JAI AT-200GE ユーザーズマニュアル

ページ / 71
AT-200GE 
- 54 - 
 
Specifications 
 
AT-200GE
 
Functions controlled via GigE 
Vision Interface 
Shutter, gain, black level, trigger mode, read out mode,  
GPIO setup, ROI (GenICam mandatory functions)  
GigE Vision Streaming Control 
Packet size, delayed (frame) read-out, inter-packet delay 
Jumbo frame can be set at max. 16K (16020) , default packet size is 1476 Byte. 
Operating temperature  
-5
C to +45
C. 
Humidity 
20 - 80% non-condensing 
Storage temp./humidity 
-25
C to 60
C./20% - 80 % non-condensing 
Vibration 
3 G (15 Hz – 200 Hz in XYZ) 
Shock 
50 G 
Regulations 
CE (EN 61000-6-2, EN 61000-6-3), FCC part 15 class B, RoHS 
Power 
10.8V to 26.4V DC. 0.61 A (Typical , Full frame ,12V input) 
                             0.68 A (Typical ,1/8 partial, +12V input) 
Lens mount 
C-mount  (Rear protrusion on C mount must be less than 4mm)   
The lens used should be designed for 3CCD cameras.  
Flange back 
17.526mm, Tolerance  +0 to –0.05mm 
Optical axis 
Center 
0.1mm 
Dimensions 
55 x 55 x 98.3 mm  (HxWxD) 
Weight 
320g 
 
Note 1: Partial scan and vertical binning can not be used at the same time. Partial scan has a priority. 
Note 2: Above specifications are subject to change without notice 
Note 3:
 
Specifications are valid after a 30 min. warm up period.