JAI AT-200GE ユーザーズマニュアル

ページ / 71
AT-200GE 
- 56 - 
 
0xA530 
ROI 3 Offset Y 
OffsetY3 
RW 
0 – 1228 
Offset Y3 
0xA534 
ROI 4 Width 
Width4 
RW 
8 - 1624   
Width 4 
W.Max 
0xA538 
ROI 4 Height 
Height4 
RW 
8 – 1236 
Height 4 
H.Max 
0xA53C 
ROI 4 Offset X 
OffsetX4 
RW 
0 – 1616 
Offset X4 
0xA540 
ROI 4 Offset Y 
OffsetY4 
RW 
0 – 1228 
Offset Y4 
0xA544 
ROI 5 Width 
Width5 
RW 
8 - 1624   
Width 5 
W.Max 
0xA548 
ROI 5 Height 
Height5 
RW 
8 – 1236 
Height 2 
H.Max 
0xA54C 
ROI 5 Offset X 
OffsetX5 
RW 
0 – 1616 
Offset X 5 
0xA550 
ROI 5 Offset Y 
OffsetY5 
RW 
0 – 1228 
Offset Y 5 
0xA080 
Fast Dump  
FastDumpEnable 
RW 
 
For enabling variable 
partial scan 
 
0xA084 
Binning   Vertical 
BinningVertical 
RW 
1=Binning OFF 
2=1/2 V Binning 
 
0xA13C 
Test Image Selector 
TestImageSeleector 
RW 
0=OFF 
4=H Rmap Scale 
5=V Ramp Scale 
6= Moving Ramp Scale 
8=Normal Color bar 
9=Vertical Color Bar 
10=Moving Color Bar 
 
0xA41C 
OB Transfer Enable 
OBTransferEnable 
RW 
 
 
 
 
 
 
Acquisition and Trigger Control 
Address  Display Name 
(JAI Control Tool) 
GenICam name 
Read / 
Write 
Size  Value / Range of value 
Description 
Default 
value 
0xA604 
Acquisition Mode 
AcquisitionMode 
RW 
0=Stop 1=Start 
Acquisition start and stop   
0xA414 
Acquisition frame rate 
AcquisitionFrameRate 
RW 
0=Full speed 
1=1/2 speed 
2=1/4 speed 
3=1/8 speed 
 
 
0xA000 
Shutter mode 
ShutterMode 
RW 
1= Programmable 
exposure in line 
2=Programmable 
exposure(us) 
3=Auto Exposure 
Constantly 
Sets exposure time for 
image capture. 
 
0xA008 
Exposure Time Raw 
ExposureTimeRaw 
RW 
0 to 1252(OFF) 
 
Flexible setting of exposure 
time ranging from 25 µs to 
48.136 ms using the LVAL 
period (L) as increment. 1L 
is 45.58us. 
1056 
0xA018 
Exposure Time (us) 
ExposureTimeAbs 
RW 
25 to 64953( OFF) 
Actual exposure time in 
microseconds, µs.  
The camera will round 
value off to match LVAL 
increments. 
64953