SGD Commands for RFID
odometer.rfid.void_resettable
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
odometer.rfid.void_resettable
Description  This command gets the RFID void label counter value or resets the counter to 
zero.
Type  getvar; setvar
This table identifies the command for this format:
Commands
Details
getvar
This command instructs the printer to respond with the current RFID void 
counter value. 
Format: ! U1 getvar "odometer.rfid.void_resettable" 
setvar
This command instructs the printer to set the RFID void counter to zero. 
Format: ! U1 setvar "odometer.rfid.void_resettable" 
"value"
 
Values: “reset” 
Example • 
This setvar example shows how the counter portion of the printer 
configuration labels looks when the RFID void counter is reset by sending:
! U1 setvar "odometer.rfid.void_resettable" "reset"