Oce North America 500XL ユーザーズマニュアル

ページ / 22
LightJet 500XL Maintenance Guide
 
×
 
 
see copyright, disclosure, use and duplication information on pg ii 
48058-A 
3-4
 Error 06 – Micropositioner Location Unknown 
Possible 
Cause: 
Micropositioner has lost servo. 
Recovery 
Method: 
Select Media/Cut and Unload. If problem persists, contact Océ. 
Error 07 – Media Guide Stuck at Home 
Possible 
Causes: 
A)  Media guides are stuck in their parked position. 
B)  Mechanical component failure.  
Recovery 
Methods: 
A)  Select Media/Cut and Unload. Inspect media guides. Clear physical 
obstruction if present. 
B)   Contact Océ. 
Error 10 – Outfeed Timeout Fault 
Possible 
Cause: 
The bottom-of-drum sensor did not sense any media within 30 seconds. 
Recovery 
Method: 
Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media. 
If error persists, contact Océ. 
Communication Failures 
Problems that prevent proper communication between the LightJet
®
 500XL and the host 
computer can cause total loss of communication, prevent certain functions, or corrupt the data 
used to generate the image. The LightJet
®
 500XL cannot detect: 
§  Whether the host computer is unable to generate the proper commands. 
§  Some cases of data corruption.
  
§  When a SCSI cable is bad or disconnected. 
§  When the wrong SCSI ID has been selected.
 
Notes: 
1
 The LightJet 500XL can detect some, but not all, types of data corruption. 
2
 The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).