2   SYSTEM CONFIGURATION 
 
2.4.8 A31TU-D3 /A31TU-DN  Teaching unit (Japanese version only) 
Teaching unit A31TU-D3 /A31TU-DN  can be easily set the teaching of positioning 
point, each parameter settings, creation of servo program, servo monitor, servo test, 
and so on without the peripheral devices. (Motion CPU module Q173CPUN-T/ 
Q172CPUN-T is usable only. Refer to the A31TU-D Teaching Unit Operating Manual 
for the usable operating system software and version.) 
 
(1)   Selection of the teaching unit 
There are no deadman switch and emergency stop terminal for the external 
safety circuit in a A31TU-DN . 
Use the A31TU-D3  to raise safety more by the deadman switch or external 
safety circuit 
(Note)
.  
Refer to the following table for selection of the teaching unit.  
 
Item A31TU-D3  A31TU-DN  
3-position deadman switch 
Provided 
(Normally open contact, double contact) 
Normally open contact is connected by 
gripping/releasing this switch. 
—— 
Emergency stop switch 
(Push lock return reset type) 
Provided 
(Normally closed contact, double contact) 
Normally closed contact is released by 
pushing switch. 
Normally closed contact is connected by 
turning to the right this switch. 
Provided 
(Normally closed contact, double contact) 
Normally closed contact is released by 
pushing switch. 
Normally closed contact is connected by 
turning to the right this switch. 
Terminal for external safety circuit  
Provided 
(Emergency stop switch × 2, 
Deadman switch × 2, 
Emergency stop input to Motion CPU × 1) 
—— 
Emergency stop input to Motion CPU 
Connect to the external safety circuit. 
(Normally closed contact input) 
The emergency stop state of Motion CPU 
occurs by releasing the normally closed 
contact of external safety circuit.   
Connect directly the emergency stop 
switch of A31TU-DN . 
(Normally closed contact input) 
The emergency stop state of Motion CPU 
occurs by pushing the emergency stop 
switch of A31TU-DN . 
Connecting cable with Motion CPU 
Q170TUD3CBL3M 
(Control panel connecting type) 
 
Q170TUDNCBL3M 
(Control panel connecting type) 
Q170TUDNCBL03M-A 
(Direct connecting type) 
Remark 
It is used as the following cases. 
• When the deadman switch is used. 
• When the double contact raises safety by 
attaching the external safety circuit. 
It is used as the following cases. 
• When the deadman switch is not used. 
• When the teaching unit is used with 
simple connecting.