Avaya 03-300430 ユーザーズマニュアル
EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1209
2000
ABRT
Response to the test request was not received within the allowable
time period.
time period.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The test tone was not detected correctly in either direction.
1. Run the test for the active Tone-Clocks on the PNs for which the
EI circuit pack under test provides a link. This will determine
whether dial tone is being supplied.
whether dial tone is being supplied.
2. Perform the
in
in Maintenance Procedures (03-300192).
1 or 2
FAIL
The test tone was detected correctly in one direction, but not the
opposite direction.
opposite direction.
1. Test for the active Tone-Clocks on the PNs for which the defective
EI board provides a link. This determines if the dial tone is
supplied.
supplied.
2. Perform the
in
in Maintenance Procedures (03-300192).
Center Stage: These failure codes are possible on a Center Stage
Switch configuration only when there is just one other PN available for
looping back the test tone.
Switch configuration only when there is just one other PN available for
looping back the test tone.
1. Perform the
in
in Maintenance Procedures (03-300192).
Table 412: Test #241 Expansion Interface 2-Way Transmission Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
4 of 5