EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1215
 
1407
ABRT
This test cannot be run on an EI board that is on the active PNC because it 
cannot be busied out. This error code indicates that PNC duplication is 
enabled.
1. Attempt to perform a PNC interchange via reset pnc 
interchange.
2. If the PNC interchange is successful, busyout the original EI circuit 
pack via busyout board location (location of the original EI 
board).
3. Retry the command.
2000
ABRT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2060
ABRT
The link on the packet bus being used to perform the test has failed.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continue to abort, enter display errors and resolve any 
PKT-INT errors.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
The test did not detect the test tone through the loop-around connection.
The packet portion of this test was not run since the circuit portion failed.
1. Test the active Tone-Clock on the PN that contains the defective EI 
circuit pack to verify that dial tone is being supplied.
2. If the Tone-Clock is healthy, enter test board location long on 
the EI circuit pack.
3. If this test continues to fail, replace the EI circuit pack or transceiver. 
Then execute test board location long on the new EI circuit 
pack.
Table 413: Test #242 Expansion Interface Lightwave Transceiver Looparound  (continued)
Error 
Code
Test 
Result
Description / Recommendation