Minimum Noncombustible Material 
Clearances
If Not Using Mantel
Note:
  If  using  a  mantel,  proceed  to  If  Using 
Mantel. If not using a mantel, follow the informa-
tion below. 
You must have noncombustible material(s) above the 
fireplace opening. Noncombustible materials (such as 
slate, marble, tile, etc.) must be at least 1/2 inch thick. 
With sheet metal, you must have noncombustible 
material behind it. Noncombustible material must 
extend at least 8" up (for all models). If noncombus-
tible material is less than 12", you must install the 
fireplace hood accessory (24" and 30" models only). 
See Figure 5 for minimum clearances.
IMPORTANT:
 If you cannot meet these minimum 
clearances, you must operate heater with chimney 
flue damper open. Go to Installing Damper Clamp 
Accessory for Vented Operation, page 12.
Heat Resistant
Material 
(A)
Noncombustible 
Requirements
Material  
for Safe 
Distance (A) 
Installation
12" or more 
Noncombustible 
material okay.
Between 8" and 12"  Install fireplace hood 
accessory (GA6050, 
GA6052 or GA6053, 
see Accessories
page 29).
Less than 8" 
Noncombustible 
material must be 
extended to at least 
8". See Between 8" 
and 12", above. If 
you cannot extend 
material, you must 
operate heater with 
flue damper open.
Figure 5 - Heat Resistant Material (Slate, 
Marble, Tile, etc.) Above Fireplace
INSTALLATION
Continued
If Using Mantel
You must have noncombustible material(s) above 
the fireplace opening. Noncombustible materials 
(such as slate, marble, tile, etc.) must be at least 
1/2 inch thick. With sheet metal, you must have 
noncombustible material behind it. Noncombustible 
material must extend at least 8 inches up (for all 
models). If noncombustible material is less than 
12", you must install the fireplace hood accessory 
(24" and 30" models only). Even if noncombustible 
material is more than 12", you may need the hood 
accessory to deflect heat away from your mantel 
shelf. See Figure 5 and Figures 6 and 7 on page 11 
for minimum clearances. 
IMPORTANT:
 If you cannot meet these minimum 
clearances, you must operate heater with chimney 
flue damper open. Go to Installing Damper Clamp 
Accessory for Vented Operation, page 12.
MANTEL CLEARANCES
In addition to meeting noncombustible material 
clearances, you must also meet required clearances 
between fireplace opening and mantel shelf. If 
you do not meet the clearances listed below, you 
will need a hood.
Determining Minimum Mantel Clearances
If you meet minimum clearance between mantel 
shelf and top of fireplace opening, a hood is not 
required (see Figure 6, page 11).
Determining Minimum Mantel Clearances 
When Using a Hood
If minimum clearances in Figure 6, page 11 are not 
met, you must have a hood. When using a hood 
there are still certain minimum mantel clearances 
required. Follow minimum clearances shown in 
Figure 7, page 11 when using hood.
NOTICE:  Surface  temperatures 
of adjacent walls and mantels be-
come hot during operation. Walls 
and  mantels  above  the  firebox 
may  become  hot  to  the  touch. 
If installed properly, these tem-
peratures meet the requirements 
of the national product standard. 
Follow all minimum clearances 
shown in this manual.