Desa VGL18NRA ユーザーズマニュアル

ページ / 32
www.desatech.com
112882-01D
8
Figure 3 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic
AIR FOR COMBUSTION 
AND VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or 
ducts. You must provide two permanent openings: 
one within 12" of the ceiling and one within 12" 
of the floor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54, 
Section 5.3, Air for Combustion and Ventilation for 
required size of ventilation grills or ducts.
IMPORTANT:
 Do not provide openings for inlet 
or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.
INSTALLATION
NOTICE: This heater is intended 
for  use  as  supplemental  heat. 
Use this heater along with your 
primary heating system. Do not 
install  this  heater  as  your  pri-
mary heat source. If you have a 
central heating system, you may 
run system’s circulating blower 
while using heater. This will help 
circulate the heat throughout the 
house. In the event of a power 
outage, you can use this heater 
as your primary heat source.
NOTICE: State or local codes may 
only allow operation of this appli-
ance  in  a  vented  configuration. 
Check your state or local codes. 
 WARNING: A qualified ser-
vice person must install heater. 
Follow all local codes.
 WARNING: If optional hand-
held remote accessory has been 
installed, make sure the selector 
switch  is  in  the  OFF  position 
before installing heater.
 WARNING: Before installing 
in a solid fuel burning fireplace, 
the  chimney  flue  and  firebox 
must be cleaned of soot, creo-
sote, ashes and loose paint by a 
qualified chimney cleaner. Creo-
sote will ignite if highly heated. 
A dirty chimney flue may create 
and  distribute  soot  within  the 
house. Inspect chimney flue for 
damage. If damaged, repair flue 
before operating heater.
  WARNING:  Seal  any  fresh 
air vents or ash clean-out doors 
located on floor or wall of fire-
place. If not, drafting may cause 
pilot  outage  or  sooting.  Use  a 
heat-resistant  sealant.  Do  not 
seal chimney flue damper. 
 WARNING: Never install the 
heater
•  in  a  bedroom  or  bathroom 
unless  installed  as  a  vented 
appliance, see page 10.
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects are less than 42 inches 
from the front, top or sides of 
the heater
•  in high traffic areas
•  in windy or drafty areas