Desa VGL18NRA ユーザーズマニュアル

ページ / 32
www.desatech.com
112882-01D
23
CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater inspected yearly by a quali-
fied service person. Heater may 
need more frequent cleaning due 
to excessive lint from carpeting, 
bedding material, pet hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INJECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt, 
lint and pet hair. Clean these air inlet holes prior to 
each heating season. Blocked air holes will create 
soot. We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.
We  also  recommend  that  you  keep  the  burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local 
computer store, hardware store or home center 
may carry compressed air in a can. You can use a 
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on 
the can. If you don't follow directions on the can, 
you could damage the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect burner, pilot and primary air inlet holes 
in rear burner for dust and dirt (see Figure 35).
3.  Blow air through the holes in the burner.
4.  Remove any large particles of dust, dirt, 
lint or pet hair with a soft cloth or vacuum 
cleaner nozzle.
Figure 35 - Injector Holder On Outlet 
Burner Tube
Burner Tube
Injector 
Holder
Primary Air 
Inlet Holes 
5.  Blow air into the primary air holes on the 
injector holder.
6.  In case any large clumps of dust have now been 
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about 
two inches from where the pilot flame comes out 
of the pilot assembly (see Figure 36). With the unit 
off, lightly blow air through the air inlet hole. You 
may blow through a drinking straw if compressed 
air is not available.
Figure 36 - Pilot Inlet Air Hole
Pilot 
Assembly
Pilot Air 
Inlet Hole
Holes in Burner
LOGS
•  If you remove logs for cleaning, refer to Install-
ing Logs,
 page 18, to properly replace logs.
•  Replace log(s) if broken or chipped (dime-sized 
or larger).
MAIN BURNER
Periodically inspect all burner flame holes with the 
heater running. All slotted burner flame holes should 
be open with yellow flame present. All round burner 
flame holes should be open with a small blue flame 
present. Some burner flame holes may become 
blocked by debris or rust, with no flame present. If 
so, turn off heater and let cool. Remove blockage, 
blocked burner flame holes will create soot.