TROUBLESHOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
 All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Broken ignitor cable
4. Bad battery
5. Ignitor electrode broken
6. Battery not installed, battery 
power  low  or  battery  not 
installed correctly (electronic 
ignition models only)
7. Ignitor electrode positioned 
wrong
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5.  Depleted  gas  supply  (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot
When ignitor button is pressed, 
there  is  spark  at  ODS/pilot  but 
no ignition
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Replace ignitor cable
4. Replace battery 
5. Replace pilot assembly
6. Install new alkaline battery in 
electronic ignitor. Verify bat-
tery is installed correctly
7. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP gas 
company
6. Clean ODS/pilot (see Cleaning 
and Maintenance, page 23) or 
replace ODS/pilot assembly
7. Replace gas control