28
WIRING DIAGRAM
Receiver
Black
On
Off
Remote
Red
Red
White
Thermopile
Gas Control 
TPTH
TH
TPTH TP
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, 
contact your local propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESA 
Heating Productsʼ Technical Service Department at 
1-866-672-6040. When calling, please have your 
model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-
cal service web site at www.desatech.com.
REPLACEMENT PARTS
Note:
 Use only original replacement parts. This 
will  protect  your  warranty  coverage  for  parts 
replaced under warranty. 
PARTS UNDER WARRANTY
Contact  authorized  dealers  of  this  product.  If 
they canʼt supply original replacement part(s), 
call DESA Heating Productsʼ Technical Service 
Department at 1-866-672-6040.
When  calling  DESA  Heating  Products,  have 
ready
•  your name
•  your address
•  model and serial numbers of your heater 
•  how heater was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they 
canʼt  supply  original  replacement  part(s)  call 
DESA Heating Products at 1-866-672-6040 for 
referral information.
When  calling  DESA  Heating  Products,  have 
ready
•  model number of your heater 
•  the replacement part number
SPECIFICATIONS
 
 
VGL18PRA 
VGL18NRA
 
 
VGL24PRA 
VGL24NRA
 
 
VGL30PRA 
VGL30NRA
Btu (Variable) 
21,000/30,000 
21,000/30,000
Type Gas 
Propane/LP 
Natural Gas
Ignition 
Electronic 
Electronic
Manifold Pressure 
8.0" W.C. 
3.5" W.C.
Inlet Gas Pressure (in. of water)
  Maximum 
14" 
10.5"
  Minimum* 
11" 
5"
* For the purpose of input adjustment