VENTILATION 
 WARNING: Provide at least 
a  1 
1
/
2
  square  foot  (1400  cm
2
opening  of  fresh,  outside  air 
while running heater. If proper 
fresh, outside air ventilation is 
not provided, carbon monoxide 
poisoning  can  occur.  Provide 
proper fresh, outside air ventila-
tion before running heater.
OPERATION
 WARNING: Review and under-
stand the warnings in the Safety 
Information section, page 2. They 
are needed to safely operate this 
heater.  Follow  all  local  codes 
when using this heater.
TO START HEATER
1.  Follow all installation, ventilation, and safety 
information.
2.  Locate  heater  on  stable  and  level  surface. 
Make sure strong drafts do not blow into front 
or rear of heater.
3.  Plug power cord of heater into a three-prong, 
grounded extension cord. Extension cord must 
be at least six feet long. Extension cord must 
be UL listed.
 
Extension Cord Wire Size Requirements
• Up to 50 ft (15.24 m) long, use 18 AWG rated 
cord.
• 51 to 100 ft (15.54 to 30.48 m) long,
  use 16 AWG rated cord.
• 101 to 200 ft (30.78 to 60.96 m) long,
  use 14 AWG rated cord.
4.  Plug extension cord into a 120 volt/60 hertz, 
3-hole, grounded outlet. Motor will start. Fan 
will turn, forcing air out front of heater.
5.  Open  propane  supply  valve  on  propane 
tank(s) slowly. Note: If not opened slowly, 
excess-flow check valve on propane tank will 
stop gas flow. You may hear a click from the 
excess-flow check valve closing. If this hap-
pens, reset the excess-flow check valve by 
closing propane supply valve and open again 
slowly.
3.  Connect hose to valve inlet (see Figure 4). 
Tighten firmly using a wrench. 
 
IMPORTANT:
 Use extra hose or piping if 
needed. Install extra hose or piping between 
hose/regulator assembly and propane tank. You 
must use the regulator supplied with heater.
4.  Open propane supply valve on propane tank(s) 
slowly. Note: If not opened slowly, excess-flow 
check valve on propane tank will stop gas flow. 
You may hear a click from the excess-flow 
check valve closing. If this happens, reset the 
excess-flow check valve by closing propane 
supply valve and open again slowly.
5.  Check all connections for leaks. Apply mix-
ture of liquid soap and water to gas joints. 
Bubbles forming show a leak that must be 
corrected.
6.  Close propane supply valve.
Figure 4 - Hose and Inlet Connector
Figure 3 - Regulator Position 
Propane 
Tank
Propane 
Supply 
Valve
Regulator
Hose
POL 
Fitting
Hose
Inlet Connector
INSTALLATION
Continued