Desa RLP155AT ユーザーズマニュアル

ページ / 44
www.desatech.com
113855-01A
6
Piezo 
Ignitor 
Automatic Control 
Valve Button
OPERATION
Continued
Figure 5 - Automatic Control Valve 
Button and Piezo Ignitor
 WARNING: Be sure motor and 
fan are running before pushing in 
automatic  control  valve  button. 
Flames could flash outside heater 
if motor and fan are not running.
6.  Push in and hold automatic control valve but-
ton (see Figure 5). Push piezo ignitor button 
(see Figure 5). Keep pushing ignitor button 
until the burner lights. When burner lights, 
keep automatic control valve button pushed in. 
Release button after 30 seconds. This activates 
the automatic control system.
 
Note:
 If heater fails to ignite, hose may have 
air in it. If so, keep automatic control valve 
button pressed and wait 20 seconds. Release 
automatic control valve button and wait 20 
seconds  for  unburned  fuel  to  exit  heater. 
Repeat this step.
NOTICE: If heater is unplugged 
or  power  outage  occurs  while 
heater  is  running,  the  thermal 
limit device will stop fuel flow. 
A few seconds occur before the 
thermal  limit  device  activates. 
During  this  short  time,  flames 
may appear outside the heater. 
This is normal. The flames will 
go out when thermal limit device 
activates.
TO STOP HEATER
1.  Tightly close propane supply valve on propane 
tank(s).
2.  Wait a few seconds. Heater will burn gas left 
in supply hose. 
3.  Unplug heater.
TO RESTART HEATER
1.  Wait five minutes after stopping heater. 
2.  Repeat steps under To Start Heater, page 5. 
STORAGE
 CAUTION: Disconnect heater 
from propane supply tank(s).
1.  Store  propane  tank(s)  in  safe  manner.  See 
Chapter 5 of Standard for Storage and Han-
dling of Liquefied Petroleum Gases, ANSI/
NFPA 58. Follow all local codes. Always store 
propane tanks outdoors. 
2.  Place plastic cover caps over brass fittings on 
inlet connector and hose/regulator assembly. 
3.  Store in dry, clean, and safe place. Do not 
store hose/regulator assembly inside heater 
combustion chamber.
4.  When taking heater out of storage, always 
check  inside  of  heater.  Insects  and  small 
animals may place foreign objects in heater. 
Remove  motor  and  other  internal  parts  if 
needed to remove foreign objects (see Service 
Procedures, page 7).