1/2 GLASS HEIGHT
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
1/2 GLASS HEIGHT
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
Figure 23 - Correct Burner Flame Pattern 
Yellow 
Tipping
Figure 24 - Incorrect Burner Flame 
Pattern 
BURNER FLAME PATTERN 
INFRARED MODELS
Figure 25 shows a correct burner flame pat-
tern.  Figure  26  shows  an  incorrect  burner 
flame pattern.
If burner flame pattern is incorrect, as shown 
in Figure 26
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 14)
•  see Cleaning, page 17
Figure 26 - Incorrect Burner Flame 
Pattern (Dual Burner Shown)
Figure 25 - Correct Burner Flame Pattern 
(Dual Burner Shown)
INSPECTING BURNER
Continued
 WARNING: If yellow tipping 
occurs,  your  heater  could  pro-
duce increased levels of carbon 
monoxide. If burner flame pattern 
shows  yellow  tipping,  proceed 
with the following instructions.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dust 
or other fine particles enter the 
heater  and  burn  causing  brief 
patches of orange flame.
BURNER FLAME PATTERN BLUE 
FLAME MODELS
Figure 23 shows a correct burner flame pat-
tern.  Figure  24  shows  an  incorrect  burner 
flame  pattern.  The  incorrect  burner  flame 
pattern  shows  yellow  tipping  of  the  flame. 
It also shows the flame higher than 1/2 the 
glass panel height.
If burner flame pattern is incorrect, as shown 
in Figure 24
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 14)
•  see Cleaning, page 17
(Models GWN6 and GWP6 will be lower due to 
lower input rating)