Desa WMN10 ユーザーズマニュアル

ページ / 60
www.desatech.com
123995-01C
14
8.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
• If  control  knob  does  not  pop  up  when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.
 
Note: If pilot goes out, repeat steps 4 thru 
7. Wait one (1) minute before lighting pilot 
again.
9.  Turn  control  knob  counterclockwise 
 to desired heating level. The main 
burner should light. Manual control heat-
ers should be used in locked positions.
10. To leave pilot lit and shut off burners only, 
turn control knob clockwise 
 to the 
PILOT position.
 WARNING: Always operate 
manual  control  heaters  at  the 
locked  positions.  Operation 
between  these  positions  may 
create a possible health hazard 
if  used  in  a  poorly  ventilated 
room. Read owner’s manual for 
complete instructions.
OPERATION
Continued
OFF
Figure 17 - Control Knob In The OFF 
Position (Manual Control Models)
Ignitor Button
Control Knob
Figure 19 - Pilot (pilot may vary from 
illustration)
Figure 18 - Control Knob In The OFF 
Position (Thermostat Models)
Ignitor Button
Control Knob
O
OT
 
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Turn off any electric power to the appli-
ance if service is to be performed.
3.  Close equipment shutoff valve (see Figure 
14, page 12.
MANUAL LIGHTING  
PROCEDURE
1.  Remove front panel (see page 10).
2.  Follow steps 1 through 7 under Lighting 
Instructions, page 13.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights.
4.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob. Now follow step 9, 
under Lighting Instructions, column 2.
5.  Replace front panel.
THERMOSTAT 
CONTROL OPERATION
Thermostat models only
The thermostatic control used on these models 
differs  from  standard  thermostats.  Standard 
thermostats simply turn on and off the burner. 
The  thermostat  used  on  this  heater  senses 
the room temperature. At times the room may 
exceed the set temperature. If so, the burner 
will shut off. The burner will cycle back on when 
room temperature drops below the set temper-
ature. The control knob can be set to any heat 
level between 1 and 5. This adjusts the amount 
of  gas  flow  to  the  burner. This  increases  or 
decreases the burner flame height. 
Note:  The  thermostat  sensing  bulb  mea-
sures the temperature of air near the heater 
cabinet.  This  may  not  always  agree  with 
room  temperature  (depending  on  housing 
construction, installation location, room size, 
open air temperatures, etc.). Frequent use of 
your heater will let you determine your own 
comfort levels.
Thermocouple
Ignitor Electrode
Pilot Burner