INSPECTING HEATER
Check  pilot  flame  pattern  and  burner  flame 
pattern often.
PILOT FLAME PATTERN
Figure 22 shows a correct pilot flame pattern. 
Figure 23 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the heater will shut down.
If  pilot  flame  pattern  is  incorrect,  as  shown 
in Figure 23
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 15)
•  see Troubleshooting, page 18
Note: The pilot flame on natural gas units will 
have a slight curve, but flame should be blue 
and have no yellow or orange color.
BURNER FLAME PATTERN
Figure 24 shows a correct burner flame pat-
tern.  Figure  25  shows  an  incorrect  burner 
flame pattern.
If burner flame pattern is incorrect, as shown 
in Figure 25
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 15)
•  see Troubleshooting, page 18
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Flame
Yellow Flame
Figure 22 - Correct Pilot Flame Pattern
Figure 23 - Incorrect Pilot Flame Pattern
Figure 24 - Correct Burner Flame Pattern 
Figure 25 - Incorrect Burner Flame 
Pattern
CLEANING
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control areas, burner and circu-
lating air passageways of heater 
clean.  Inspect  these  areas  of 
heater  before  each  use.  Have 
heater  inspected  yearly  by  a 
qualified service person. Heater 
may need more frequent clean-
ing  due  to  excessive  lint  from 
carpeting, bedding material, pet 
hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.