POSSIBLE CAUSE
1. Ignitor electrode positioned 
wrong
2. Ignitor electrode broken
3. Ignitor  electrode  not  con-
nected to ignitor cable
4. Ignitor  cable  pinched  or 
wet
5. Broken ignitor cable
6. Bad ignitor
7. Piezo ignitor nut is loose
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob is not in pilot 
position
3. Control  knob  not  fully 
pressed  in  while  pressing 
ignitor button 
4. Air  in  gas  lines  when  in-
stalled
5. Depleted  gas  supply  (pro-
pane/LP gas)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
1. Not  enough  combustion/
ventilation air
REMEDY
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched 
by  any  metal  or  tubing. 
Keep ignitor cable dry
5. Replace ignitor cable
6. Replace ignitor
7. Tighten  nut  holding  piezo 
ignitor. Nut is located inside 
heater cabinet at top
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn  control  knob  to  pilot 
position
3. Turn to PILOT/IGN position. 
Fully  press  in  control  knob 
while pressing ignitor button
4. Continue  holding  down 
control knob. Repeat ignit-
ing  operation  until  air  is 
removed
5. Contact  local  propane/LP 
gas company
6. Clean  ODS/pilot  (see 
Cleaning,  page  16)  or  re-
place ODS/pilot assembly
7. Replace gas regulator
1. Refer to Air for Combustion 
and  Ventilation  require-
ments (page 5)
OBSERvED PROBLEM
When  ignitor  button  is 
pressed in, there is no spark 
at ODS/pilot
When  ignitor  button  is 
pressed in, there is a spark 
at ODS/Pilot but no ignition
Moisture/condensation  no-
ticed on windows