Desa RCLP100V ユーザーズマニュアル

ページ / 28
www.desatech.com
103908-01E
4
Air For Combustion 
And Heating
Fuel
THEORY OF OPERATION
The Fuel System:
 The hose/regulator assembly attaches to the propane gas supply. The propane gas 
moves through the automatic control valve and out the nozzle.
The Air System:
 The motor turns the fan. The fan pushes air into and around the combustion chamber. 
This air is heated and provides a stream of clean, hot air.
The Ignition System:
 The spark transformer ignitor lights the main burner.
The Safety Control System:
 This system causes the heater to shut down if the flame goes out.
VENTILATION
 WARNING: Follow the mini-
mum fresh, outside air ventila-
tion  requirements.  If  proper 
fresh, outside air ventilation is 
not provided, carbon monoxide 
poisoning  can  occur.  Provide 
proper fresh, outside air ventila-
tion before running heater.
Provide a fresh air opening of at least 3 ft
2
 (0.28 m
2
for each 100,000 Btu/Hr rating. Provide extra fresh 
air if more heaters are being used.
INSTALLATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
Note:
  Some  parts  are  located 
differently on some models.
Figure 2 - Cross Section Operational View
Clean 
Heated 
Air Out 
(Front)
Combustion Chamber
Hose/Regulator 
Assembly
Nozzle
Fan
Cool 
Air In 
(Back)
Power Cord
Air for 
Combustion 
and Heating
Fuel
 WARNING: Test all gas piping 
and connections for leaks after 
installation or servicing. Never 
use an open flame to check for 
a leak. Apply a mixture of liquid 
soap  and  water  to  all  joints. 
Bubbles  forming  show  a  leak. 
Correct all leaks at once.
1.  Provide propane supply system (see Propane 
Supply
, page 3).
2.  Connect fuel gas connector fitting on hose/
regulator assembly to propane tank(s). Turn 
counterclockwise into threads on tank valve. 
Tighten firmly using wrench. IMPORTANT: 
Tighten regulator with vent pointing down. 
Pointing vent down protects regulator from 
weather damage.
3.  Connect  hose  to  inlet  connector. Tighten 
firmly using a wrench. IMPORTANT: Extra 
hose or piping may be used if needed. Install 
extra hose or piping between hose/regulator 
assembly and propane tank. You must use the 
regulator supplied with heater.
4.  Open propane supply valve on propane tank(s) 
slowly. Note: If not opened slowly, excess-
flow check valve on propane tank will stop 
gas flow. If this happens, close propane supply 
valve and open again slowly.