Desa RCLP100V ユーザーズマニュアル

ページ / 28
www.desatech.com
103908-01E
5
OPERATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
TO START HEATER
1.  Follow all installation, ventilation and safety 
information.
2.  Locate  heater  on  stable  and  level  surface. 
Make sure strong drafts do not blow into front 
or rear of heater.
3.  Make sure the control knob is in the OFF 
position.
5.  Check all connections for leaks.
6.  Close propane supply valve.
INSTALLATION
Continued
Figure 3 - Regulator With Vent Pointing 
Down
Hose
Regulator
Vent 
(pointing 
down)
Fuel Gas 
Connector
Supply Valve
Propane 
Tank
Figure 4 - Hose and Inlet Connector
Hose
100,000 Btu/Hr 
Model Shown
Inlet 
Connector
4.  Plug power cord of heater into a three-prong, 
grounded extension cord. Extension cord must 
be at least 6 ft. (2 m) long, UL/CSA listed, and 
of a proper size.
 
Extension Cord Size Requirement
 
Up to 100 ft. (30 m) long, use 16 AWG rated 
cord.
 
101 to 200 ft. (31 to 60 m) long, use 14 AWG 
rated cord.
5.  Plug extension cord into a 120 volt/60 hertz, 
3-hole, grounded outlet. Motor will start. Fan 
will turn, forcing air out front of heater.
6.  Open propane supply valve on propane tank(s) 
slowly. Note: If not opened slowly, excess-
flow check valve on propane tank will stop 
gas flow. If this happens, close propane supply 
valve and open again slowly.
7.  Press and hold in control knob. Turn counter-
clockwise to the LOW position. Heater should 
ignite within a few seconds.
 
Note:
 If heater fails to ignite, hose may have 
air in it. If so, keep automatic control valve 
button pressed and wait 20 seconds. Release 
automatic control valve button and wait 20 
seconds  for  unburned  fuel  to  exit  heater. 
Repeat step 7.
8.  After  heater  ignites,  wait  30  seconds  then 
release the control knob. This activates the 
automatic control system.
9.  When  burner  remains  lit,  set  heater  at  the 
desired heat level by turning the control valve 
counterclockwise. If burner goes out, turn off 
gas. Turn control knob fully clockwise to the 
lowest position. Check fuel supply. If adequate 
fuel is available, restart heater beginning at 
step #1.
TO STOP HEATER
1.  Tightly close propane supply valve on propane 
tank(s).
2.  Wait a few seconds. Heater will burn gas left 
in supply hoses.
3.  Turn control knob to the OFF position.
4.  Unplug heater.