GAS SUPPLY
PROPANE/LP GAS MODEL 125-R ONLY
Propane gas and propane tank(s) are to be fur-
nished by the user.
Use  this  heater  only  with  a  propane  vapor 
withdrawal supply system. See Chapter 5 of the 
Standard for Storage and Handling of Liquefied 
Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA 
B149.2. Your local library or fire department will 
have this booklet.
The amount of propane gas ready for use from 
propane  tanks  varies. Two  factors  decide  this 
amount.
1.  The amount of liquid propane gas in tank(s)
2.  The temperature of tank(s)
The chart below shows the minimum number of 45 
kg (100 lb) tanks needed to run the heater. Connect 
tanks together with a manifold.
 
Average Temperature 
Number Of Tanks 
  °C (°F) At Tank Location 
45 kg (100 lb)
 
4° (40°) to 0° (32°) 
 
 
Below 0° (32°) 
3
Less gas is vaporized at lower temperatures. Your 
local propane gas dealer will help you select the 
proper supply system.
NATURAL GAS MODEL 125-RN ONLY
The user must furnish the natural gas supply and 
the connections to the heater.
Regulate the natural gas supply down from a mini-
mum 7" w.c. to a maximum of 1/2 psi. The natural 
gas supply capacity should be able to supply a 
minimum of 125 cubic feet of gas at pressure for 
each heater connected to the system.
Consult your natural gas supplier for proper sizing 
of the natural gas supply lines.
Follow all local ordinances and codes. In the ab-
sence of local ordinances and codes, refer to the 
National Fuel Gas Code Handbook, NFPA54/ANSI 
Z223.1 and the Natural Gas Installation Code, CAN/ 
CGA B149.1
.
VENTILATION
 WARNING: Provide at least 
a  .35  m
2
  (3.75  ft
2
)  opening  of 
fresh, outside air while running 
heater. If proper fresh, outside 
air  ventilation  is  not  provided, 
carbon  monoxide  poisoning 
can occur. Provide proper fresh, 
outside  air  ventilation  before 
running heater.
INSTALLATION 
INSTRUCTIONS
Read  these  instructions  care-
fully. Read and adhere to these 
instructions. Do not allow any-
one  who  has  not  read  these 
instructions to assemble, light, 
adjust or operate this heater.
Do  not  attempt  to  operate  the 
heater with any gas other than 
that  indicated  on  the  heater 
nameplate.
For the U.S. and/or Canada, the installation of this 
appliance must comply with local and/or Provin-
cial codes or, in the absence of these codes, with 
the (U.S.) National Fuel Gas Code, ANSI Z223.1 
– Latest Edition (for natural and propane/LP gas 
operation) and with the (U.S) Standard for the 
Storage  and  Handling  of  Liquefied  Petroleum 
Gases, ANSI/NFPA 58 (for propane/LP gas opera
-
tion) or with the current (Canadian) CAN/CGA 
B149.1 and B149.2 installation codes.
This heater (including hose and regulator assembly 
if applicable) must be inspected before each use 
and at least annually by a qualified service person. 
If the hose for model 125-R shows evidence of 
excessive abrasion or wear or if the hose is cut, it 
must be replaced prior to the heater being put into 
operation. The replacement hose assembly shall be 
that specified by the manufacturer.