LOCATING HEATER
The heater (and propane/LP gas supply cylinder 
if applicable) must be located on a hard, flat, level 
surface to minimize the risk of accidental tipping. If 
an propane/LP gas supply cylinder is used (propane/
LP model only), the cylinder should be adequately 
restrained to prevent accidental tipping. DO NOT 
operate this heater with the supply cylinder in 
any other than the upright position.
This appliance must be installed only in locations 
where the potential for physical damage to the 
appliance (i.e., due to physical contact) is reduced 
to a minimum.
The installer must inform the owner/operator of 
this appliance that precautions must be taken to 
protect the appliance from physical damage.
This appliance produces radiant heat. Therefore, 
it  must  be  located  at  least  6  feet  away  from 
any propane/LP gas container and must not be 
directed  toward  any  propane/LP  gas  container 
within 20 feet.
The heater must be installed in a location such that 
it will not be exposed directly to water spray, rain 
and/or dripping water.
Use of this heater in a draft/windy area decreases 
its efficiency. If possible, operate the unit in a 
draft free area.
PIPING
FOR MODEL 125-R (FOR USE WITH 
PROPANE/LP GAS ONLY)
This model may be connected to a self-contained 
propane/LP gas supply system using the hose and 
regulator assembly supplied with the appliance 
OR, it may be connected to a permanently installed 
propane/LP gas supply system.
If  connected  to  a  self-contained  propane/LP 
gas supply system, the hose assembly must be 
inspected prior to each use of the heater. If it is 
evident that there is excessive abrasion or wear or 
if the hose is cut, it must be replaced prior to the 
heater being put into operation.
 WARNING: Never use a fork 
lift truck type cylinder.
The connection of model 125-R to a propane/LP 
cylinder must be made in a well ventilated area 
using the regulator and hose assembly supplied 
with the appliance. DO NOT attempt to adjust 
this regulator. It has been preset at the factory 
to provide safe and proper operation of the ap-
pliance. Use a 7/8" open end wrench to connect 
the  POL  fitting  (supplied  with  the  propane/LP 
regulator) to the propane/LP cylinder. Turn the 
POL nut in a counterclockwise direction (left hand 
thread) until tight. DO NOT use pipe compound  
on POL threads.
The heater must be located at least six feet away 
from any propane/LP cylinder and must not be 
directed toward any propane/LP cylinder within 
20  feet.  If  more  than  one  heater  is  used,  they 
and the supply cylinders must be separated by at 
least 20 feet.
The gas supply must be turned off at the propane/LP 
supply cylinder when the heater is not in use.
When the heater is to be stored indoors, the connec-
tion between the propane/LP supply cylinder and 
the heater must be disconnected and the cylinder 
removed from the heater and stored in accordance 
with Chapter 5 of the Standard for the Storage and 
Handling of Liquefied Petroleum Gases. ANSI/
NFPA 58 (U.S.) OR CAN/CGA B149.2 (Canada)
.
If connected to a permanently installed propane/LP 
supply system, the system requires the use of a 
two-stage gas regulator assembly which is nor-
mally provided by your propane/LP dealer as part 
of the propane/LP supply system. Consult with 
your local propane/LP dealer for details concern-
ing proper equipment and installation.
FOR MODEL 125-RN (FOR USE 
WITH NATURAL GAS ONLY)
Piping must be clean and free from scale or burrs.
Install regulator supplied with heater. Connect with 
1/2" NPT nipple to control valve.
Connect the appliance to an appropriately designed 
and installed fuel supply system. This system must 
include an approved manual shutoff valve which 
is readily accessible and is located within 6 feet 
of the appliance. Additionally, a sediment trap or 
drip leg must be located upstream of this manual 
shutoff valve. Refer to the appropriate (natural gas) 
installation code noted above. If a flexible connec-
tor is used, it must be of an approved type.
 WARNING: Never use a flame 
for gas leak testing.