SYMPTOM
Burner fails to light
Pilot  lights  but  goes  out  when 
automatic  control  valve  button 
is released
Burn rate is low
POSSIBLE CAUSE
1. Gas supply valve closed
2. Excess-flow  check  valve 
closed  (propane/LP  units 
only)
3. Blockage in burner orifice
4. Piezo  ignition  system  not 
sparking
1. Not enough warm-up time
2. Low gas pressure
3. Thermocouple loose or needs 
to be replaced
4. Automatic control valve needs 
to be replaced
1. Main burner valve not fully 
open
2. Plugged gas orifices
3. Low gas pressure
4. Low fuel supply
REMEDY
1. Open gas supply valve slowly
2. Close  propane  supply  valve 
on propane tank and reopen 
slowly
3. Replace burner orifice
4. Assure ignitor electrode gap is 
5.0 mm (.195 in). Check wire 
lead for damage Replace piezo 
ignitor and/or ignitor electrode 
as necessary. Do not bend elec-
trode, this may cause breakage
1. Relight, hold automatic control 
valve button in 45 seconds
2. Check for proper gas supply
3. Tighten connection or replace 
thermocouple
4. Replace  automatic  control 
valve
1. Fully open main burner valve 
by  pushing  in  control  knob 
and turning counterclockwise 
towards HIGH position until 
it stops
2. Replace gas orifice
3. Check  gas  supply;  check 
regulator output
4. Consult gas supplier to deter-
mine adequate supply. If using 
propane/LP gas, the tank could 
be empty
TROUBLESHOOTING
 WARNING: Never attempt to service heater while it is connected 
to propane supply, operating or hot. Severe burns can occur.