7
SHUTTING OFF HEATER
•  For short periods of time, turn the main burner 
off by turning control knob clockwise to the 
PILOT position.
•  For extended periods of non use, turn appli-
ance completely off by turning control knob 
clockwise to the PILOT position, press knob 
slightly,  then  turn  knob  fully  clockwise  to 
the OFF position. Note: For propane/LP gas 
models, also turn off gas supply cylinder.)
PILOT BURNER ADJUSTMENT
1.  Remove pilot adjustment cap. The pilot adjust-
ment cap is a slotted screw located in front 
of the PILOT designation stamped on top of 
valve body just below control knob.
2.  Adjust pilot key to provide properly sized 
flame. Rotate the key clockwise to decrease 
flame or counterclockwise to increase flame.
3.  Replace pilot adjustment cap.
MAINTENANCE
 WARNING:
•  Never  attempt  to  service 
heater while it is connected to 
propane supply, operating or 
hot. Severe burns can occur.
•  Keep  heater  clear  and  free 
from  combustible  materials, 
gasoline and other flammable 
vapors and liquids.
•  Do not block the flow of com-
bustion or ventilation air.
1.  Keep heater clean. Clean heater annually or as 
needed to remove dust and debris. If heater is 
dirty or dusty, clean heater with a damp cloth. 
Use household cleaners on difficult spots. 
2.  Inspect heater before each use. Check connec-
tions for leaks. Apply mixture of liquid soap 
and water to connections. Bubbles forming 
show a leak. Correct all leaks at once. 
3.  Inspect hose/regulator assembly before each 
use. If hose is highly worn or cut, replace.
4.  Have heater inspected yearly by a qualified 
service agency.
OPERATING 
INSTRUCTIONS
Continued
SPECIFICATIONS
Propane/LP Model 125-R
Rating 
125,000 Btu/Hr (131,882 kj)
Fuel 
Propane Vapor Only
Fuel Consumption per Hour
 
 
5.17 liters (1.3 gallon) 
 
 
2.6 kg (5.8 pounds) 
Supply Pressure To Regulator (for input adjustment)
 
Maximum 
1380 kPa (200 psi)
 
Minimum  
138 kPa (20 psi)
Manifold Pressure  2.3 kPa (9.5 inches W.C.)
Weight
 
Heater 
17.69 kg (39 lbs)
 
Shipping 
20.86 kg (46 lbs)
Size - L x W x H 
40.6 x 45.7 x 109.2 cm
 
 
(16 x 18 x 43 inches)
Min Temperature 
-29 °C (-20° F) Surrounding
 
 
 Air Temperature
Natural Gas Model 125-RN
Rating 
125,000 Btu/Hr (131,882 kj)
Fuel 
Natural Gas Only
Fuel Consumption 
 
per Hour 
3.5 m
3
 (125 ft
3
Manifold Pressure   1.5 kPa (6 inches W.C.)
Weight
 
Heater 
17.69 kg (39 lbs)
 
Shipping 
20.86 kg (46 lbs)
Size - L x W x H 
40.6 x 45.7 x 109.2 cm
 
 
(16 x 18 x 43 inches)
Min Temperature 
-29 °C (-20° F) Surrounding
 
 
 Air Temperature