CONNECTING TO GAS SUPPLY
  WARNING:  This  appliance 
requires  a  3/8"  NPT  (National 
Pipe Thread) inlet connection to 
the pressure regulator.
 WARNING: A qualified ser-
vice person must connect heater 
to  gas  supply.  Follow  all  local 
codes.
  WARNING:  For  natural  gas, 
never connect heater to private (non-
utility) gas wells. This gas is com-
monly known as wellhead gas.
IMPORTANT:
 For natural gas, check gas line 
pressure before connecting heater to gas line. Gas 
line pressure must be no greater than 10.5 inches of 
water. If gas line pressure is higher, heater regula-
tor damage could occur.
  CAUTION:  For  propane/LP 
gas, never connect heater directly 
to  the  propane/LP  supply.  This 
heater requires an external regu-
lator  (not  supplied).  Install  the 
external  regulator  between  the 
heater and propane/LP supply. 
For propane/LP gas, the installer must supply an 
external  regulator. The  external  regulator  will 
reduce incoming gas pressure. You must reduce 
incoming gas pressure to between 11 and 14 inches 
of water. If you do not reduce incoming gas pres-
sure, heater regulator damage could occur. Install 
the external regulator with the vent pointing down 
as shown in Figure 14. Pointing the vent down 
protects it from freezing rain or sleet.
INSTALLATION
Continued
Figure 14 - External Regulator With Vent 
Pointing Down
External Regulator
Propane/LP 
Supply Tank
Vent 
Pointing 
Down
  CAUTION:  Use  only  new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
large enough diameter to allow 
proper gas volume to heater. If 
pipe is too small, undue loss of 
volume will occur.
Typical Inlet Pipe Diameter
30,000 Btu/Hr Models - 1/2" or greater
Installation must include equipment shutoff valve, 
union and plugged 1/8" NPT tap. Locate NPT tap 
within reach for test gauge hook up. NPT tap must 
be upstream from heater (see Figure 15, page 13).
IMPORTANT:
 Install an equipment  shutoff valve 
in an accessible location. The equipment  shutoff 
valve is for turning on or shutting off the gas to 
the appliance.
Apply  pipe  joint  sealant  lightly  to  male  NPT 
threads. This  will  prevent  excess  sealant  from 
going into pipe. Excess sealant in pipe could result 
in clogged heater valves.
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas. 
Install sediment trap in supply line as shown in 
Figure 15, page 13. Locate sediment trap where 
it is within reach for cleaning. Locate sediment 
trap where trapped matter is not likely to freeze. 
A sediment trap traps moisture and contaminants. 
This keeps them from going into heater controls. If 
sediment trap is not installed or is installed wrong, 
heater may not run properly.