Desa CB36P ユーザーズマニュアル

ページ / 36
www.desatech.com
117437-01D
1
OPERATING FIREPLACE
Continued
MANUAL LIGHTING 
PROCEDURE
1.. Remove.glass.door.(see.Removing/Re-
placing Glass Door, page 18).
.. Follow.steps.1.through.8.under.Lighting 
Instructions, page 20).
3.. Press.gas.control.knob.and.light.pilot.with.
match.
4.. Keep.gas.control.knob.pressed.in.for.30.
seconds. after. lighting. pilot..After. 30. sec-
onds,  release  gas  control  knob.  Follow 
steps.10.through.11.under.Lighting Instruc-
tions
, page 20).
5.. Replace.glass.door.(see.Removing/Re-
placing Glass Door, page 18).
ELECTRONIC IGNITION 
SySTEM
LIGHTING 
INSTRUCTIONS
1.  STOP!  Read  the  safety  information, 
page.0.
2.  Turn  off  all  electrical  power  to  the  fire-
place.
3.. Turn.wall.switch.to.the.OFF.position.
4.. Open.lower.louver.panel.
5.. Turn. equipment. shutoff. valve. clockwise.
. to. the. OFF. position. (see. Figure.
34)..Do.not.force.
6.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety  information,  page  20.  If  you  don’t 
smell.gas.go.to.the.next.step.
7.. Turn. equipment. shutoff. valve. counter-
clockwise.
.to.the.ON.position..Do.
not.force.
8.. Close.lower.louver.panel.
9.  Turn on all electric power to fireplace.
10..Turn.wall.switch.to.the.ON.position.
Figure 35 - Pilot
Pilot.
Burner
Ignitor
Sensor.
Rod
Figure 34 - Turning Equipment Shutoff 
Valve to the OFF Position
11..Visually.locate.pilot..Ignitor.should.begin.
to. spark. and. main. burner. should. ignite.
once flame appears at pilot.
• If lighting appliance for the first time each 
season,  it  may  take  several  attempts 
before. supply. gas. can. reach. pilot. and.
main.burner.
•.If.appliance.will.not.stay.lit.after.several.
attempts, follow instructions in To Turn 
Off  Gas  To  Appliance
,  and  call  your 
service.technician.or.gas.supplier.
NOTICE: During initial operation 
of  a  new  heater,  the  burning  of 
residues from the manufacturing 
process  of  the  firebox  and  logs 
will produce a paper-burning smell 
and orange flames. Open a window 
for the first few hours of operation 
to adequately vent this smell.
TO TURN OFF GAS 
TO APPLIANCE
1.. Turn.off.wall.switch.
.. Turn.off.all.electric.power.to.appliance.if.
service.is.to.be.performed.
3.. Open.lower.louver.panel.
4.. Turn. equipment. shutoff. valve. clockwise.
.to.OFF..Do.not.force.
5.. Close.lower.louver.panel.
OPTIONAL WIRELESS 
REMOTE OPERATION
Note:  The  WRC  receiver  and  hand-held 
remote control kit must be purchased sepa-
rately  (see  Accessories,  page  31).  Follow 
installation  instructions  included  with  the 
remote control.
1.. Turn.equipment.shutoff.valve.to.ON.posi-
tion..You.can.now.turn.burner.on.and.off.
with.hand-held.remote.unit.