5
LOGS
•  If  you  remove  logs  for  cleaning,  refer  to 
Installing Logs and Glowing Embers, page 
19, to properly replace logs.
•  Use  a  vacuum  cleaner  to  remove  any 
carbon.buildup.on.logs.
•. Replace.log(s).if.broken..See.Replacement 
Parts,.page.31.
•. Replace. ember. material. periodically. as.
needed..See.Replacement Parts, page 31.
VENTING SYSTEM
Conduct. annual. inspection. of. the. venting.
system.following.these.guidelines:
1.. Check.areas.of.venting.system.that.are.
exposed. to. the. weather. corrosion. (rust.
CLEANING AND MAINTENANCE
Continued
spots  or  streaks  and  in  extreme  cases, 
holes).. Have. these. items. replaced. im-
mediately by a qualified service person.
2.  Remove the vent cap and shine a flashlight 
into.vent..Remove.any.foreign.material.
3.. Check. for. evidence. of. excessive. con-
densation..Continuous.condensation.can.
cause corrosion of caps, pipes and fittings 
and.can.be.caused.by.having.excessive.
lateral runs, too many elbows or exterior 
portions.of.the.system.being.exposed.to.
cold.weather.
4.  Inspect joints to verify that no pipe sec-
tion  or  fitting  has  been  distributed  and 
loosened.. Check. mechanical. supports.
such.as.wall.straps.for.rigidity.
SPECIFICATIONS
(V)CB36N
•  Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Natural
•  Orifice  Size  (Main  Burner):  #45  DMS 
(0.08")
•. Ignition:.Millivolt
•. Manifold.Pressure:.3.5".w.c..(0.87.kPa)
•. Min..Inlet.Supply.Pressure:.5.5".w.c..(1.1.kPa)
(V)CB36P
•  Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Propane/LP
•  Orifice  Size  (Main  Burner):  #55  DMS 
(0.05")
•. Ignition:.Millivolt
•. Manifold.Pressure:.10".w.c..(.5.kPa)
•. Min..Inlet.Supply.Pressure:.11".w.c..(.7.kPa)
(V)CB36NE
•  Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Natural
•  Orifice  Size  (Main  Burner):  #45  DMS 
(0.08")
•. Ignition:.Electronic
•. Manifold.Pressure:.3.5".w.c..(0.87.kPa)
•. Min..Inlet.Supply.Pressure:.5.5".w.c..(1.1.kPa)
(V)CB36PE
•  Maximum Input Rating: 18,000 Btu/hr
•. Gas.Type:.Propane/LP
•  Orifice  Size  (Main  Burner):  #55  DMS 
(0.05")
•. Ignition:.Electronic
•. Manifold.Pressure:.10".w.c..(.5.kPa)
•. Min..Inlet.Supply.Pressure:.11".w.c..(.7.kPa)
ALL MODELS
•  Fireplace Dimension HxWxD (Actual size of firebox measurements do not include nailing 
flanges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
•. Carton.Dimension.HxWxD:.36.75".x.38".x.16.5".(93.3.x.96.5.x.41.3.cm)
SERVICE HINTS
When Gas Pressure Is Too Low
•. pilot.will.not.stay.lit
•. burners.will.have.delayed.ignition
•  heater will not produce specified heat
•  for propane/LP units, propane/LP gas sup-
ply.may.be.low
You.may.feel.your.gas.pressure.is.too.low..If.
so, contact your local natural or propane/LP 
gas.supplier.
TECHNICAL SERVICES
You.may.have.further.questions.about.installa-
tion, operation, or troubleshooting. If so, con-
tact DESA Heating, LLC at 1-866-672-6040. 
When. calling. please. have. your. model. and.
serial.numbers.of.your.heater.ready.
You can also visit DESA Heating, LLC’s web 
site.at.
www.desatech.com
.