Desa CB36P ユーザーズマニュアル

ページ / 36
www.desatech.com
117437-01D
7
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1..Gas.control.knob.not.fully.
pressed.in
..Gas. control. knob. not.
pressed.in.long.enough
3..Equipment. shutoff. valve.
not.fully.open
4..Pilot. flame. not. touching.
thermocouple,  which  al-
lows thermocouple to cool, 
causing.pilot.to.go.out..This.
problem.could.be.caused.
by.one.or.more.of.the.fol-
lowing:
. A).Low.gas.pressure
. B).Dirty.or.partially.clogged.
pilot
5..Thermocouple.connection.
loose.at.control.valve.
6..Thermocouple.damaged
7..Control.valve.damaged
1. Burner orifice clogged
..Inlet. gas. pressure. is. too.
low
3..Thermopile. leads. dis-
connected.or.improperly.
connected
4..Thermopile.is.defective
5..Improper.venting.or.exces-
sive.blockage
1..Manifold. pressure. too.
low
2. Burner  porting  or  orifice 
clogged
1. Burner orifice is clogged or 
damaged
..Damaged.burner
3..Gas.regulator.defective
1..Residues. from. manufac-
turing.processes.and.logs.
curing
OBSERVED PROBLEM
Manual Ignition System Only
Pilot  lights  but  flame  goes 
out. when. control. knob. is.
released
Burner. does. not. light. after.
pilot. is. lit. or. cycles. during.
operation.
Delayed.ignition.at.burner
Burner backfiring during com-
bustion
Slight. smoke. or. odor. during.
initial.operation
REMEDY
1..Press. in. gas. control. knob.
fully
..After  pilot  lights,  keep  gas 
control. knob. pressed. in. 30.
seconds
3..Fully.open.equipment.shut-
off.valve
4..A).Contact.local.natural.or.
propane/LP.gas.company
. B).Clean.pilot.(see.Cleaning 
and Maintenance, page 24) 
or.replace.pilot.assembly
5. Hand  tighten  until  snug, 
then.tighten.1/4.turn.more
6..Replace.pilot.assembly
7..Replace.control.valve
1..Clean.burner.(see.Cleaning 
and Maintenance, page 24) 
or replace burner orifice
..Contact.local.propane/LP.or.
natural.gas.company
3..Reconnect.leads
4..Replace.thermopile
5..Have. the. vent. system. in-
spected,  including  the  ter-
mination.cap..Remove.any.
restriction.or.obstruction
1..Contact.local.propane/LP.or.
natural.gas.company
..Clean.burner.(see.Cleaning 
and Maintenance, page 24) 
or replace burner orifice
1..Clean.burner.(see.Cleaning 
and Maintenance, page 24) 
or replace burner orifice
..Replace.damaged.burner
3..Replace.gas.control
1..Problem.will.stop.after.a.few.
hours.of.operation