Desa CB36P ユーザーズマニュアル

ページ / 36
www.desatech.com
117437-01D
8
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1..Turning. gas. control. knob.
to.HI.position.when.burner.
is.cold
..Air.in.gas.line
3..Dirty. or. partially. clogged.
burner orifice
1..Flame. impingement. on.
logs
..Debris. around. burner. air.
mixer
1..Metal. expanding. while.
heating. or. contracting.
while.cooling
1..Battery.is.not.installed.or.
battery.is.power.is.low
1..High.or.gusting.winds
..Low.line.pressure
3..Pilot.is.partially.clogged
4..Improper.or.restricted.vent-
ing
5. Clogged  burner  tube, 
blocked orifice or improper 
burner air adjustment
6..Bad.thermopile.or.thermo-
couple
7..Vent. cap. improperly. in-
stalled.or.blocked
OBSERVED PROBLEM
Heat. produces. a. whistling.
noise.when.burner.is.lit
Glass.soots
Fireplace.produces.a.clicking/
ticking noise just after burners 
are.lit.or.shut.off
Remote.does.not.function
Fireplace.shuts.off.in.use.
Burner backfiring during com-
bustion
REMEDY
1..Turn.gas.control.knob.to.LO.
position.and.let.warm.up.for.
a.minute
..Operate. burner. until. air. is.
removed. from. line.. Have.
gas.line.checked.by.pro.
pane/LP. or. natural. gas.
company
3..Clean.burner.(see.Cleaning 
and Maintenance, page 24) 
or replace burner orifice
1. Adjust  the  log  set  so  the 
flame does equipment shut-
off.valve
..Inspect.the.opening.at.the.
base. of. the. burner. to. see.
that. it. is. not. packed. with.
any.type.of.material
1..This. is. normal.. If. noise. is.
excessive, contact qualified 
service.person
1..Replace. 9-volt. batteries. in.
receiver.and.remote.control
1..Fireplace.has.been.tested.for.
up. to. 40. mph. winds.. How-
ever,  extreme  conditions 
may. occur.. See. Lighting 
Instructions
, page 20 or 21
..Check.local.propane/LP.or.
natural.gas.company
3..Clean. pilot. (see. Cleaning 
and  Maintenance,  page 
4)
4..Locate.and.correct.all.vent.
conditions.(see.Checking for 
Proper Venting
, page 10)
5..Clean. burner. tube. and.
orifice,  adjust  air  shutter 
(see. Inspecting  Burners
page.3)
6..Replace. faulty. compo-
nents
7..Check. for. proper. installa-
tion. or. remove. debris. or.
blockage