PRODUCT FEATURES
These.are.a.few.facts.that.can.help.you.un-
derstand  and  enjoy  your  vented  decorative 
fireplace:
•. The.(V)CB36N(E).and.(V)CB36P(E).series.
of  vented  decorative  fireplaces  may  be 
recessed into an exterior chase, an interior 
flush wall enclosure or a framed-in corner 
installation.
•. Models. (V)CB36N. and. (V)CB36P. are.
equipped.with.a.millivolt.gas.control.system.
that.does.not.require.electricity.to.operate..
A piezo ignitor is provided to light the pilot 
without.using.matches.or.lighters.
•. Models. (V)CB36N(E). and. (V)CB36P(E).
are. equipped. with. an. electronic. ignition.
system.that.requires.10.VAC.to.operate..
An.electrode.ignitor.automatically.lights.the.
pilot flame when the fireplace is turned on.
•  These fireplaces can accept any approved 
4". B-Type. venting. system. and. must. be.
terminated.vertically.through.the.roof.using.
Through.exterior.wall.
enclosed.in.a.chase
Corner.
Installation
Flush.with.a.wall
Figure 2 - Common Fireplace Locations 
25"
(63.5 cm)
36"
(91.4 cm)
36"
(91.4 cm)
Figure 3 - Fireplace Bottom Dimensions 
a. listed. type. vent. cap. only.. See. venting.
instructions.starting.on.page.8.for.proper.
venting.requirements.
•  These vented fireplaces require indoor air 
for.combustion.and.must.be.installed.in.a.
room of sufficient size to provide adequate 
fresh.air.for.safe.and.proper.operation..The.
room.intended.for.installation.must.be.of.
sufficient  size  to  meet  the  requirements 
for an unconfined space as defined in the 
National  Fuel  Gas  Code,  ANSI  Z223.1/
NFPA 54,  Air for Combustion and Ventila-
tion
. If sufficient air for combustion is not 
available.a.makeup.air.kit.model.AK4.may.
be. required. to. provide. outside. air. to. this.
appliance.. Check. your. local. codes. as. to.
specific requirements for make up air.
•  This fireplace may be installed in any room 
of.the.house.provided.all.local.codes.and.
these.installation.instructions.are.followed.
PRE-INSTALLATION PREPARATION
LOCATION AND SPACE 
REqUIREMENTS
Determine the safest and most efficient loca-
tion for your DESA Heating, LLC direct-vent 
fireplace.  Make  sure  that  rafters  and  wall 
studs.are.not.in.the.way.of.the.venting.system..
Choose.a.location.where.the.heat.output.is.
not affected by drafts, air conditioning ducts, 
windows.or.doors..Figure..shows.some.com-
mon.locations..Be.aware.of.all.restrictions.and.
precautions.before.deciding.the.exact.location.
for your fireplace and termination cap.
When deciding the location of your fireplace, 
follow.these.rules:
•  Do not connect this fireplace to a chimney 
flue servicing a separate solid fuel burning 
fireplace or appliance.
•  Do to high temperatures, do not locate this 
fireplace in high traffic areas, windy or drafty 
areas, or near furniture or draperies.
•. Proper.clearances.must.be.maintained.
•  If your fireplace is to be installed directly on 
carpeting, vinyl, tile or any combustible mate-
rial other than wood, it must be installed on a 
metal.or.wood.panel.extending.the.full.width.
and depth of the fireplace (see Figure 3).
•  Only trim kits supplied by DESA Heating, 
LLC.shall.be.used.in.the.installation.of.this.
fireplace, see Accessories, page 31.
•. Do. not. install. aftermarket. vent. dampers..
Manual.or.automatic.vent.dampers.are.not.
approved.for.use.with.this.appliance.