Desa BVDR30 ユーザーズマニュアル

ページ / 28
www.desatech.com
901746-01E
17
 
TROUBLEShOOTING
Continued 
 
POSSIBLE CAUSE
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Pilot  adjustment  screw 
closed
6. Pilot is clogged
7. Low gas pressure
1. Control  knob  not  fully 
pressed in
2. Control knob not pressed in 
long enough
3. Equipment  shutoff  valve  not 
fully open
4. Pilot  flame  not  touching 
thermocouple,  which  al-
lows thermocouple to cool, 
causing  pilot  flame  to  go 
out. This problem could be 
caused  by  one  or  both  of 
the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
pilot 
5. Thermocouple  connection 
loose at control valve 
6. Thermocouple damaged
7. Control valve damaged
1. Burner orifice clogged
2. Inlet  gas  pressure  is  too 
low
3. Burner  orifice  diameter  is 
too small
4. Thermocouple  leads  dis-
connected  or  improperly 
connected
1. Pilot flame needs adjusting
2. Wrong pilot orifice
REMEDY 
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while 
in PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Adjust  pilot  flame  for  ap-
proximately 2" blue flame
6. Clean  pilot  (see  Cleaning 
and Maintenance, page 15) 
or replace pilot assembly
7. Replace gas control
1. Press in control knob fully
2. After pilot lights, keep con-
trol  knob  pressed  in  30 
seconds
3. Fully open equipment shut-
off valve
4. A) Contact local natural gas 
company
 
  B) Clean pilot (see Cleaning 
and Maintenance, page 15) 
or replace pilot assembly 
5. Hand  tighten  until  snug, 
then tighten 1/4 turn more
6. Replace thermocouple
7. Replace control valve
1. Clean burner orifice
2. Contact  local  natural  or 
propane/LP gas company
3. Replace burner orifice
4. Reconnect leads 
1. Adjust  pilot  flame  for  ap-
proximately 2" blue flame
2. Replace pilot orifice set
OBSERvED PROBLEM
When  ignitor  button  is 
pressed, there is spark at pilot 
but no ignition (GA9050A-1 
Only)
Pilot lights but flame goes out 
when control knob is released 
(GA9050A-1 Only)
Burner  does  not  light  after 
pilot is lit (GA9050A-1 Only)
Delayed  ignition  burner 
(GA9050A-1 Only)