Desa CRN30 ユーザーズマニュアル

ページ / 32
www.desatech.com
17
107883-01H
OPERATING HEATER
Continued
THERMOSTAT 
OPERATION
The thermostatic control used on these models 
differs from standard thermostats. Standard 
thermostats simply turn on and off the burner. 
The thermostat used on this heater senses the 
room  temperature. At  times  the  room  may 
exceed the set temperature. If so, the burner 
will shut off. The burner will cycle back on 
when room temperature drops below the set 
temperature. The control knob can be set to 
any 2 comfort level between HI and LO. All 
plaques will turn off and on.
Note:
 
The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This may not always agree with room tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.) Frequent use of your heater will 
let you determine your own comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 7, page 8).
2.  Follow steps 1 through 5 under Lighting 
Instructions, page 16.
3.  With thermostat control knob pressed in, 
strike  match.  Hold  match  to  pilot  until 
pilot lights.
4.  Keep thermostat control knob pressed in 
for 30 seconds after lighting pilot. After 30 
seconds, release control knob. Follow step 
8 under Lighting Instructions, page 16.
5.  Replace front panel.
INSPECTING HEATER
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pattern. Figure 
26 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple. 
This will cause the thermocouple to cool. When the 
thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 26
•  turn heater off (see To Turn Off Gas to Appli-
ance, page 15, depending on your model) 
•  see Troubleshooting, page 19
Note: 
The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Flame
Yellow Flame
Figure 25 - Correct Pilot Flame Pattern
Figure 26 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 27 shows a correct burner flame pattern. Fig-
ure 28 shows an incorrect burner flame pattern. 
If burner flame pattern is incorrect, as shown in 
Figure 28
•  turn heater off (see To Turn Off Gas to Appli-
ance,
 page 15, depending on your model) 
•  see Troubleshooting, page 19 
Figure 27 - Correct Burner Flame Pattern 
Figure 28 - Incorrect Burner Flame 
Pattern