Desa CRN30 ユーザーズマニュアル

ページ / 32
www.desatech.com
19
107883-01H
TROUBLESHOOTING
 WARNING: Turn off and unplug heater and let cool before servicing. 
Only a qualified service person should service and repair heater. 
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
 All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  positioned 
wrong
2. Ignitor electrode broken
3. Ignitor  electrode  not  con-
nected to ignitor cable
4. Ignitor cable pinched or wet
5. Broken ignitor cable
6. Bad piezo ignitor
7. Piezo  ignitor  nut  is  loose 
(piezo ignition models only)
8. Battery not installed, battery 
power  low  or  battery  not 
installed correctly (electronic 
ignition models only)
1.  Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not fully pressed 
in while pressing ignitor button 
(non-thermostat models only)
  Thermostat control knob not 
fully pressed in while press-
ing ignitor button (thermostat 
models only) 
3. Air in gas lines when installed
4. Depleted gas supply (propane/
LP gas)
5. ODS/pilot is clogged
6. Gas  regulator  setting  is  not 
correct
7. Thermostat control knob is not 
in pilot position (thermostat 
models only)
REMEDY 
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
5. Replace ignitor cable
6. Replace piezo
7.  Tighten  nut  holding  piezo 
ignitor. Nut is located inside 
heater cabinet at top 
8. Install  new  alkaline  battery 
in  electronic  ignitor. Verify 
battery is installed correctly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn to PILOT/IGN position. 
Fully  press  in  control  knob 
while pressing ignitor button 
(non-thermostat models only)
  Fully press in thermostat control 
knob while pressing ignitor but-
ton (thermostat models only)
3. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
4. Contact local propane/LP gas 
company
5. Clean ODS/pilot (see Cleaning 
and Maintenance, page 18) or 
replace ODS/pilot assembly
6. Replace gas regulator
7. Turn thermostat control knob 
to pilot position 
OBSERVED PROBLEM
When ignitor button is pressed 
in,  there  is  no  spark  at  ODS/
pilot
When ignitor button is pressed 
in, there is a spark at ODS/Pilot 
but no ignition