Figure 2 - Typical Two-Sided Fireplace 
Installation 
INTRODUCTION
Models (V)GL36ST/P and (V)GL36STE/EP are 
decorative  gas  appliances  that  use  a  millivolt 
gas control and piezo pilot or an electronic gas 
control valve with an electronic ignition system 
respectively. These systems require a 6", B-type 
venting system for operation.
The  6"  B-type  vent  is  not  supplied  by  FMI 
PRODUCTS,LLC . For installation guidelines, 
check your B-vent instructions.
  WARNING:  This  gas  appli-
ance must not be connected to
a chimney flue servicing a solid
fuel burning appliance.
Models (V)GL36ST and (V)GL36STE are smooth 
face units for natural gas only. The (V)GL36STP 
and  (V)GL36STEP  are  smooth  face  units  for 
propane/LP gas only. To determine which type of 
gas your unit is approved and tested for, check the 
rating plate on the lift-out plate located inside the 
firebox under the access panel.
BEFORE YOU BEGIN
Before beginning the installation of your appli-
ance, read these instructions through completely.
This appliance and its approved components are 
safe when installed according to this installation 
manual  and  are  operated  as  recommended  by 
FMI  PRODUCTS,  LLC.  Unless  you  use  FMI 
PRODUCTS,LL  approved  components  tested 
for this appliance, 
YOU MAY CAUSE A FIRE 
HAZARD!
The FMI PRODUCTS,LLC warranty will be voided 
by and FMI PRODUCTS,LLC disclaims any respon-
sibility for the following actions :
A)  Modification  of  the  appliance  or  any  of 
the  components  manufactured  by  FMI 
PRODUCTS,LLC unless otherwise permitted 
by FMI PRODUCTS,LLC.
B)  Use of any component part not approved by 
FMI PRODUCTS,LLC in combination with 
this appliance.
C)  Installation and/or operation in a manner other 
than instructed in this manual.
D)  The burning of anything other than the type of 
gas approved for use in this gas appliance.
This appliance, when installed, must be electrically 
grounded in accordance with local codes or, in the 
absence of local codes, with the National Electrical 
Code, ANSI/NFPA 70.
The installation must conform with local codes or, in 
the absence of local codes, with the current National 
Fuel Gas Code, ANSI Z223.1/NFPA 54.
This appliance complies with ANSI Z21.50 as a 
Vented Gas Appliance and is listed and tested by 
the PFS Corporation.
  WARNING:  Installation  of 
this appliance should be done
by  a  qualified  service  person
well  trained  in  the  installation
of  such  appliances.  You  will
also need a building permit from
your local Building and Safety 
Commissioner before installing
this appliance; otherwise your
insurance  company  may  not
cover this appliance.
NOTICE: This appliance is not 
intended to be used as a primary
source of heat.
SELECTING LOCATION
To determine the safest and most efficient location 
for your appliance, you must take into consider-
ation the following guidelines:
1.  The location must allow for proper clearances 
(see Clearances, page 6). Note: This decora-
tive appliance is not designed for outdoor 
installation.
2.  The location should be in a place where drafts, 
air conditioning ducts, windows or doors will 
not affect fireplace heat output.
3.  A location that avoids the cutting of joists 
or roof rafters will make installation easier. 
Figure 2 shows a typical two-sided fireplace 
installation.
IMPORTANT: All  fireplace  openings  must  be 
located at least 3 feet from facing wall or com-
bustible material.
Existing 
Side 
Wall
4" From Opening to 
Perpendicular Wall
Projected 
Wall