FIREPLACE 
INSTALLATION
Continued
FRAMING
Construct  framing  using  dimensions  shown  if 
Figures 6, 7 and 8. (Use the figure applicable to 
your  application.)  Figure  6  shows  the  framing 
dimensions prior to having the appliance in place. 
Once the unit has been fitted, bring studs in against 
nailing flanges located on the side of the appliance 
making sure a 1" clearance is maintained as shown 
in Figure 7.
If the fireplace is to be installed directly on carpet-
ing, tile (other than ceramic) or any combustible 
material other than wood flooring the fireplace 
must  be  installed  upon  a  metal  or  wood  panel 
extending the full width and depth of the fireplace 
(see Figure 8). The platform must be solid, flat and 
fully supported.
Figure 6 - Framing Dimensions Prior to 
Placing Appliance
Figure 7 - Securing Appliance with 
Nailing Flanges
Figure 8 - Appliance Must Be Installed  
on a Wood or Metal Panel if Being 
Installed on Any Combustible Material 
Other Than Wood
52 
3
/
4
"
(1340 mm)
Min.
46"
(11688 mm)
22 
3
/
4
"
(578 mm)
VENT PIPE INSTALLATION
A 6", B-1 type gas vent pipe is a double-wall, vent-
ing system (not supplied) which must be installed 
during rough framing of the appliance. Any B-1 
type gas vent system may be used for proper vent-
ing as long as the vent system is installed per the 
vent manufacturer’s recommendations.
FMI PRODUCTS,LLC supplies this appliance with 
a tapered starter pipe for a  snug fit. Slide B-1 type 
vent pipe over this starter pipe until vent pipe is 
fully seated. Secure this first section of B-vent 
pipe by strapping the connector around the vent 
pipe and then tightening the strap (not supplied) 
with any 1/8" nut and bolt (see Figure 9). Note: 
Visually inspect for proper vent connection by 
looking  inside  top  of  appliance.  If  connection 
does not appear to be correct, contact your local 
service technician.
Figure 9 - Installing B-Vent Pipe
Nailing Flanges
1" Min. to Combustibles
Prepared Framing
Nails or Screws
As Required by Design as 
Long as Ceiling Clearances 
are Maintained
49" Minimum
(Diagonal)
B-1 Type 
Vent (Not 
Supplied)
Strap (Not 
Supplied) 
(Fasten with 
#6 Screw or 
Bolt)