Thermo Products 100n ユーザーズマニュアル

ページ / 67
All installations and services must be performed by qualified service personnel. 
II.  FURNACE SPECIFICATIONS 
 
CHX3 SERIES 
 
MODEL NO. 
CHX3-75 
CHX3-100 
CHX3-125 
BTU/HR INPUT (High fire/ Low fire) 
75,000 / 52,000 
100,000 / 
70,000 
125,000 / 
87,500 
BTU/HR OUTPUT (High fire/ Low fire) 
71,000 / 49,000 
95,000 / 66,000 
115,000 / 
82,000 
 
 
 
 
HEIGHT OF CASING 
44-1/4” 44-1/4” 44-1/4” 
WIDTH OF CASING 
17” 21” 24” 
DEPTH OF CASING 
27-1/2” 27-1/2” 27-1/2” 
WARM AIR OUTLET 
15 x 18 
19 x 18 
22 x 18 
RETURN AIR INLET 
25 x 16 
25 x 16 
25 x 16 
 
 
 
 
DIA. OF FLUE 
2” 3” 3” 
DIA. OF COMBUSTION 
AIR INTAKE 
2” 3” 3” 
 
 
 
 
CFM from .2” & .5” w.c.  
EXTERNAL STATIC PRESSURE 
COOLING COOLING COOLING 
       @COOLING TAP A  
1000 1200 1400 
       @COOLING TAP B  
800 1000 1200 
       @COOLING TAP C  
1200 1400 1600 
       @COOLING TAP D 
1400 1600 2000 
 
 
 
 
 
HEATING HEATING HEATING 
      @HEATING TAP A  (High fire/Low fire) 
931 / 760 
1243 / 1015 
1556 / 1270 
 
 
 
 
TEMPERATURE RISE 
70 / 60 
70 / 60 
70 / 60 
BLOWER MOTOR HP 
.5 .75  1 
 
 
 
 
POWER CHOKES 
2.65 Mh 
2.1 Mh 
LARGEST RECOMMEDED 
AIR CONDITIONER 
3.5 Ton 
4 Ton 
5 Ton 
SIZE OF FILTERS 
24-3/4” x 15-3/4”
24-3/4” x 15-3/4”  24-3/4” x 19-3/4”
NOTES: 
1.  BTU output based on annual fuel utilization efficiency rated by manufacturer. 
2.  On all outlet and inlet dimensions, the first dimension is width. 
3.  To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is 
required.