All installations and services must be performed by qualified service personnel. 
 
 
36 
 Figure 9 
 
 
C.  INDUCER BLOWER ASSEMBLY 
 
Inspect the pressure switch and tubing connections and inspect the blower/assembly 
for warpage, deterioration and carbon or other build-up.  If necessary, clean the 
accessible portions of the housing and blower with a damp cloth.  Vacuum to remove 
any lint or dust from the motor assembly. 
 
 
D.  INSPECTING THE VENTING SYSTEM 
 
The venting system should be inspected during the annual maintenance check-up or 
during each subsequent service call. 
 
Check all vent pipes for restrictions due to soot, or carbon build-up, as well as foreign 
matter, or any materials, that cause the venting system to restrict the proper venting of 
combustion products.  If a restriction is found, the flue vent must be cleaned or 
replaced to ensure proper venting.