For models working with batteries follow 
instructions below, whereas in the case of mains 
operated models the transformer has already 
been placed inside the machine and needs no 
further installation.
The batteries are supplied without liquid, 
therefore they must be filled up with the 
appropriate acid before they can be used.
 
Take special care when handling the 
acid as it is corrosive,  If it should come 
into contact with skin or eyes, wash 
abundantly with water and consult a 
doctor.
 
The W345B & W355B machines use two 12 volt 
batteries, the W365B & W375B machines use 
four 6 volt batteries. 
Study the 
illustrations then fit 
the batteries and 
connect the links 
supplied as 
indicated.
Plug the battery 
socket into the 
machine as shown.
Fold over the flaps 
to cover the battery 
tops, then lower the 
tank unit to safely 
cover exposed 
working parts.
 
The three solenoid valve bodies may be removed 
by turning them through 45 degrees and lifting 
them away to reveal the plunger and seating of 
each valve. These should be cleaned of scale and 
of any other foreign matter.
Regularly inspect the squeegee for damage or 
wear to the lips. The lips may be easily replaced 
by unscrewing the retaining strips, remove the 
lips, replace with new, then screw the cover strips 
back again to retain them.
 
Important:periodically clean the suction 
filters; this is very important not to 
reduce the suction capability of the 
squeegee.
 
+
-
+
-