350-2100 cfm Dryers 
Chapter 7: Troubleshooting 
53 of 58 
 
 
PROBLEM  
POSSIBLE CAUSE  
CORRECTIVE ACTION 
Loss or reduction of 
process air temperature. 
 
A. Process heaters are  
faulty. 
 
A. Check for open or 
shorted heaters. Replace if 
required. Check the fuses. 
 
 B. Solid-state temperature 
controller faulty. 
B. Replace. 
 
C. Process temperature 
was adjusted in error by 
plant personnel. 
C. Make sure that plant  
personnel are aware of the 
proper temperature 
setpoint. A sign posted next 
to the control would be 
helpful. 
 
Loss or reduction in drying 
capacity. 
A. Process heaters are 
faulty.  
A. Replace. 
 
B. Desiccant beds are  
contaminated.  
B. Replace desiccant.  
 
C. Material being dried  
differs from material  
specified at the time of 
purchase.  
 
C. Drying systems are 
designed for the material 
which was originally 
specified. Different 
materials may need a 
longer residence time or 
different drying 
temperature. 
 
D. Break in flex hose 
to/from drying hopper. 
D. Inspect for air leaks; 
replace if necessary. 
 
 E. Airflow valves sticking 
or failing to shift.  
 
E. Check for proper 
operation of linear valve 
actuator. Check fusing. 
Repair or replace if 
necessary.  
 
F.    Blower fins filled with 
dust or contaminants. 
F. Remove blower 
sideplate, clean baffles, 
replace. Replace filter 
elements.