Chamberlain WD962KPEV ユーザーズマニュアル

ページ / 48
25
Option C
FLOOR INSTALLATION
Inside
Gar
age
Wa
ll
1.1C  
Carefully measure the position of 
both sensor brackets so they will 
be the same distance from the 
wall and unobstructed.
Use an extension bracket (not provided) or wood block to raise the sensor bracket if needed.
Insid
e
Garage
Wa
ll
1.2C  
Attach the sensor brackets to 
the fl oor using concrete anchors 
(not provided).
(not provided)
1.3C  
Slide the carriage bolt (H17) 
into the slot on each sensor.
H17
Ins
de
Gar
ag
e
Wa
ll
1.4C  
Insert the bolt through the hole in 
the sensor bracket and attach with 
the wing nut (H18). The lenses on 
both sensors should point toward 
each other. Make sure the lens is not 
obstructed by the sensor bracket.
H18
Install the Safety Reversing Sensors
1
RED
WHITE
WHITE
GREY
WHITE
WHITE
ED
RED
RED
RE
WH
WHIT
HARDWARE
Insulated Staple (30)
2.1A  
Run the wire from both sensors 
to the garage door opener. Attach 
the wire to the wall and ceiling 
with the staples.
2.3A  
Insert the white wires into the 
white terminal on the garage door 
opener. Insert the white/black wires 
into the grey terminal on the garage 
door opener.
2.2A  
Strip 7/16 inch (11 mm) of 
insulation from each set of 
wires. Separate the wires. 
Twist the white wires together. 
Twist the white/black wires 
together.
Wire the Safety 
Reversing Sensors
2
To insert or remove the wires 
from the terminal, push in the 
tab with a screwdriver tip.
Staple
7/16" 
(11 mm)
PRE-WIRED INSTALLATIONS: If your 
garage already has wires installed for 
the safety reversing sensors, refer to the 
instructions on the following page.
INSTALLATION WITHOUT PRE-WIRING