Attach the warning labels
3
3.1  
Attach the entrapment warning label on the wall near the door control with tacks or 
staples.
3.2  
Attach the manual release/safety reverse test label in a visible location on the inside 
of the garage door. 
Install the Protector System
®
Introduction
Be sure power is NOT connected to the 
garage door opener BEFORE installing 
the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH 
from a closing garage door:
•   Correctly connect and align the 
safety reversing sensor. This 
required safety device MUST NOT be 
disabled.
•   Install the safety reversing sensor so 
beam is NO HIGHER than 6" 
(15 cm) above garage fl oor.
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
The safety reversing sensors must be connected and aligned correctly before the garage 
door opener will move in the down direction.
The sending sensor (with an amber LED) transmits an invisible light beam to the receiving 
sensor (with a green LED). If an obstruction breaks the light beam while the door is closing, 
the door will stop and reverse to the full open position, and the garage door opener lights will 
fl ash 10 times. 
NOTE: For energy effi ciency the garage door opener will enter sleep mode when the door is 
fully closed. The sleep mode shuts the garage door opener down until activated. The sleep 
mode is sequenced with the garage door opener light bulb; as the light bulb turns off the 
sensor LEDs will turn off and whenever the garage door opener lights turn on the sensor 
LEDs will light. The garage door opener will not go into the sleep mode until the garage door 
opener has completed 5 cycles upon power up.
When installing the safety reversing sensors check the following:
•  Sensors are installed inside the garage, one on either side of the door.
•   Sensors are facing each other with the lenses aligned and the receiving sensor lens does 
not receive direct sunlight.
•   Sensors are no more than 6 inches (15 cm) above the fl oor and the light beam is 
unobstructed.
Safety Reversing Sensor
6" (15 cm) max. above floor
Invisible Light Beam 
Protection Area