NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
carbon  Monoxide  poisoning:  early  signs  of 
carbon monoxide poisoning are similar to the 
flu with headaches, dizziness and/or nausea. if 
you have these signs, obtain fresh air immedi-
ately. turn off the gas supply to the appliance 
and have it serviced by a qualified professional, 
as it may not be operating correctly.
operation and care oF Your
appLiance
Appliance operation may be controlled by the 
following  means:  the  factory  provided  unit-
mounted  ON-OFF  control  switch,  a  remotely 
located optional wall switch or optional remote 
control.  See Figure 1.
Burn-in period
During the first few fires of this appliance there 
will  be  some  odor  due  to  the  curing  of  the 
paint and burning off of lubricants used in the 
manufacturing process. 
Depending on your use, the burn-in period may 
take a few hours or a few days.  
Keep  Your  House  WeLL  VentiLated 
durinG tHe curinG process.  tHe odor 
and  Haze  eMitted  durinG  tHe  curinG 
process can Be Quite noticeaBLe and 
MaY set oFF a sMoKe detector.
If an optional blower is installed, Do not turn it 
on during the Burn-In period. 
A white film may develop on the glass front 
during the first few fires as part of the curing 
process.  The glass should be kept clean during 
the first two weeks of use to prevent the film from 
baking on (making it very difficult to remove).  
See Glass Cleaning on Page 4.
Table 1 shows the units' gas orifice size for 
the elevations indicated.
Maximum manifold pressure is 3.5 in. w.c. (0.87 
kPa) for natural gas and 10 in. w.c. (2.49 kPa) 
for LP/Propane gas.
Do  not  use  these  appliances  if  any  part  has 
been under water. Immediately call a qualified, 
professional service technician to inspect the 
appliance and to replace any parts of the control 
system and any gas control which have been 
under water.
Ne pas se servir de cet appareil s'il a été plongé 
dans l'eau, complètement ou en partie.  Appeler 
un technicien qualifié pour inspecter l'appareil 
et remplacer toute partie du système de con-
trôle et toute commande qui ont été plongés 
dans l'leau. 
Test gage connections are provided on the front 
of the millivolt and electronic gas control valve 
(identified OUT for the manifold side and IN for 
inlet pressure.  A 1/8" NPT test gage connection 
is provided on the electronic gas control valve 
adjacent to the outlet to the main burner.  
Minimum  inlet  gas  pressure  to  these  appli-
ances is 5.0  inches water column (1.24 kPa) 
for  natural  gas  and  11  inches  water  column 
(2.74 kPa) for propane for the purpose of input 
adjustment.
Maximum inlet gas supply pressure to these 
appliances is 10.5 inches water column (2.61 
kPa)  for  natural  gas  and  13.0  inches  water 
column (3.23 kPa) for propane.
The  appliance  must  be  isolated  from  the  gas 
supply piping system (by closing its individual 
manual shut-off valve) during any pressure testing 
of the gas supply piping system at test pressures 
equal to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve 
must  be  disconnected  from  the  gas  supply 
piping system during any pressure testing of 
that system at pressures in excess of 1/2 psig 
(3.5 kPa).
These appliances must not be connected to a 
chimney or flue serving a separate solid fuel 
burning appliance.
Table 1
Figure 1
WarninG:  FaiLure to coMpLY WitH 
tHe  instaLLation  and  operatinG 
instructions  proVided  in  tHis 
docuMent  WiLL  resuLt  in  an  iM-
properLY instaLLed and operatinG 
appLiance, VoidinG its WarrantY. 
anY  cHanGe  to  tHis  appLiance 
and/or  its  operatinG  controLs 
is danGerous.  iMproper instaL-
Lation  or  use  oF  tHis  appLiance 
can cause serious injurY or deatH 
FroM  Fire,  Burns,  expLosion  or 
carBon Monoxide poisoninG.
WarninG:  cHiLdren  and  aduLts 
sHouLd Be aLerted to tHe Hazards 
oF HiGH surFace teMperatures. use 
caution around tHe appLiance to 
aVoid Burns or cLotHinG iGnition. 
YounG  cHiLdren  sHouLd  Be  care-
FuLLY superVised WHen tHeY are in 
tHe saMe rooM as tHe appLiance.
WarninG:  do not pLace cLotHinG 
or  otHer  FLaMMaBLe  MateriaLs 
on or near tHis appLiance.
aVertisseMent:  surVeiLLer  Les 
enFants.  Garder Les VêteMents, 
Les MeuBLes, L'essence ou autres 
LiQuides  à  Vapeur  inFLaMMaBLes 
Loin de L'appareiL.
l
e
d
o
M
.
o
N
e
z
i
s
e
c
if
ir
O
n
o
it
a
v
e
l
E
t
e
e
F
)
s
r
e
t
e
m
(
.t
a
N
.
p
o
r
P
5
3
V
D
L
E
8
3
#
3
5
#
0
0
5
4
-
0
)
2
7
3
1
-
0
(
0
4
V
D
L
E
7
3
#
"
2
6
0
.
0
5
4
V
D
L
E
6
3
#
2
5
#
Any safety guard or screen removed for ser-
vicing the appliance must be replaced prior to 
operating the appliance.
Piezo Ignitor
Gas
Supply
Line
ON/OFF
Switch
ON
OFF
Shut-Off Valve
(Orientation
As Shown)
Gas Valve
Air Shutter
Adjustment Arm
Gas Line Access Plate Not Installed
At The Factory.  It Is Included In
The Installation Instruction Bag.
Right Corner Post