Lennox Hearth L30 DVF-2 ユーザーズマニュアル

ページ / 29
CARE AND OPERATION 
 
PAGE 16 
FOR YOUR SAFETY READ BEFORE LIGHTING 
WARNING: If you do not follow these instructions 
exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life. 
A. This appliance has a pilot which must be lit.  When 
lighting the pilot, follow these instructions exactly. 
B. BEFORE LIGHTING smell all around the appli-
ance area for gas.  Be sure to smell next to the 
floor because some gas is heavier than air and will 
settle on the floor. 
WHAT TO DO IF YOU SMELL GAS: 
•  Do not try to light any appliance. 
•  Do not touch any electric switch; do not use 
any phone in your building. 
•  Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s in-
structions. 
•  If you cannot reach your gas supplier, call the 
fire department. 
C. Use only your hand to push in or turn the gas con-
trol knob. Never use tools.  If the knob will not 
push in or turn by hand, don’t try to repair it, call a 
qualified service technician.  Force or attempted 
repair may result in a fire or explosion. 
D.  Do not use this appliance if any part has been un-
der water.  Immediately call a qualified service 
technician to inspect the appliance and to replace 
any part of the control system and any gas control 
which has been under water. 
 
Gas Control Knobs 
 
 
 
  
  
 
LIGHTING AND SHUTDOWN INSTRUCTIONS 
1.  STOP!  Read the safety information on this page or on label 
(on appliance). 
2.  Turn off all electrical power to the appliance (unplug blower 
power cord). Make sure the burner ON/OFF switch is in the 
OFF position. 
3.  To gain access to the gas controls, swing the control access 
door open.  The control access door is located directly under 
the window. 
4.  Push in gas control knob slightly and turn clockwise 
3
 to 
“OFF.” 
NOTE:  Knob cannot be turned from “PILOT” to “OFF” 
unless knob is pushed in slightly.  Do not force. 
5. Wait five (5) minutes to clear out any gas.  Then smell for 
gas, including near the floor.  If you smell gas, STOP!  Fol-
low “B” in the safety information above on this label.  If you 
don’t smell gas, go to the next step. 
6. Visually locate the pilot located in the center of the firebox 
beneath the rear ceramic log. 
7. Turn knob on gas control counterclockwise 
4
 to “PILOT.”  
8. This appliance contains a spark ignition system (piezo ig-
niter), which is used to light the pilot. Push in the gas control 
knob all the way and hold it in.  Immediately press the button 
on the piezo igniter located to the left of the gas control knob.  
The spark produced by the piezo igniter should light the pilot.  
Continue to hold the control knob in for about one (1) minute 
after the pilot is lit.  Release the gas control knob and it will 
pop back up.  Pilot should remain lit. 
•If it goes out, repeat steps 4 through 8. 
•If the knob does not pop up when released, stop and im-
mediately call your service technician or gas supplier. 
•If the pilot will not stay lit after 3 or 4 tries, turn the gas con-
trol knob to “OFF” and call your service technician or gas 
supplier. 
9.  Turn gas control counterclockwise 
4
 to “ON.”  Use rocker 
switch, located either on the control panel or the exterior 
side panel, to operate main burner.  Adjust variable pres-
sure dial (RB Regulator / Flame Height Control) to set 
burner flame to desired heat output. 
10.  Swing the control access door closed. 
11. Turn on electrical power to the appliance (plug in blower 
power cord. See page 16, Circulation Blower Operation.) 
 
TO TURN OFF GAS TO THE APPLIANCE 
1.  Turn off all electric power to the appliance if service is to be 
performed. 
2.  To gain access to the gas controls, swing the control ac-
cess door open. The control access door is located directly 
under the window. 
3.  Push in gas control knob slightly and turn clockwise 
3
 to 
“OFF.” 
 
NOTE: Knob cannot be turned from “PILOT” to “OFF” 
unless knob is pushed in slightly. Do not force. 
4.  Swing the control access door closed. 
  Piezo Igniter 
Inlet  
Pressure  
Tap
Wiring
Terminals
 Outlet Pressure Tap 
Pilot Adjustment Screw 
Convertible HI/LO 
Regulator 
Regulator 
Cap 
Thermocouple  Igniter  
Electrode
 
Pilot 
Hood
 
Thermopile 
Pilot Assembly