PROPANE CONVERSION 
 
PAGE 18 
PROPANE CONVERSION PROCEDURE 
(Only required if Propane gas is used) 
This appliance is designed to operate on natural gas, or propane 
(LP).  It is factory set for use with natural gas and requires field 
conversion for use with propane. The use of other fuels or com-
bination of fuels will degrade the performance of this system 
and may be dangerous. 
 
When converting to Propane Gas (LP), it may be necessary to 
install (as a minimum) 3 feet of vertical pipe from the appli-
ance prior to an offset to ensure optimum product performance. 
This may be necessary due to variations in vent configuration 
and other numerous factors which affect exhaust flow and air 
delivery such as BTU value, ambient temperature, wind condi-
tions, altitude, etc.
 
 
The conversion kit provided with this appliance contains com-
ponents required to convert this appliance from use with natural 
gas to use with propane (LP) Gas. All of the components in the 
propane conversion kit must be installed in order for the appli-
ance to operate safely on propane. 
 
Installation Tools / Supplies 
7/16” Open end wrench 
Small standard screwdriver 
Pipe sealant compound (must be rated for use with LPG gas) 
 
Parts List 
•  Propane RB Regulator conversion screw (Red  indicates LP gas) 
•  Burner Orifice (If you are at an elevation above 4500 feet do not use 
the orifice provided in this kit. Contact your gas supplier to obtain a 
smaller orifice) 
•  Pilot Orifice 
•  Label, Converted to (LP) Propane – Affix to valve 
•  Label, Converted to (LP) Propane – Affix to stove body 
 
Avertissement: cet équipement de conversion sera installé par 
une agence qualifiée de service conformément aux instructions 
du fabricant et toutes exigences et codes applicables de 
l’autorisés avoir la juridiction.  Si l’information dans cette in-
struction n’est pas suivie exactement, un feu, explosion ou pro-
duction de protoxyde de carbone peut résulter le dommages 
causer de propriété, perte ou blessure personnelle de vie.  
L’agence qualifiée de service est esponsable de l’installation 
propre de cet équipment.  L’installation n’est pas propre et 
compléte jusqu’à l’opération de l’appareil converti est chéque 
suivant les critères établis dans les instructions de propriétaire 
provisionnées avec l’équipement. 
 
IN CANADA: 
The conversion shall be carried out in accordance with the re-
quirements of the provincial authorities having jurisdiction and 
in accordance with the requirements of the CAN1-B149.1 and .2 
Installation code. 
 
La conversion devra être effectuée conformément aux recom-
mandations des autorités provinciales ayant juridiction et con-
formément aux exigences du code d’installation CAN1-B149.1 
ET.2. 
 
 
PROPANE Conversion Procedure 
1.  Turn off Gas - Turn gas control knob to the off position, and 
shut off the gas supply to the valve. If necessary, disconnect 
appliance from gas supply. 
2.  Caution: The gas supply shall be shut off prior to disconnect-
ing the electrical power, before proceeding with the conver-
sion. Unplug blower power cord. 
3.  If the installation is at an elevation below 4500 feet, proceed 
to step 4. 
If you are at an elevation above 4500 feet, do not use the 
orifice provided in this kit. Contact your gas supplier to obtain a 
smaller orifice).
 
4.  Burner Orifice Installation Procedure: 
a. Remove glass door. 
b.  Remove logs, burner cover, and burner. 
c.  Use a 7/16” open-end wrench to remove gas burner ori-
fice. 
d.  Replace the burner orifice with the appropriate burner 
orifice (see instruction #3). 
e.  Use pipe sealing compound rated for LP gas. BE VERY 
CAREFUL THAT THE PIPE COMPOUND DOES NOT GET 
INSIDE OF THE ORIFICE (THIS COULD RESULT IN 
PLUGGING OF THE ORIFICE). Using a 7/16” open-end 
wrench to tighten orifice - DO NOT OVER TIGHTEN (fin-
ger tight, then 1/2 turn maximum). *Make sure the ori-
fice is inserted fully into the primary air shutter fixed 
opening. 
5. 
Adjust primary air shutter. Burner Air Shutter opening to be: 
Natural Gas – 1/2 open, Propane 3/4 open. Some adjustment 
from standard may be necessary for the desired flame char-
acteristics (see Burner Flame Appearance, page 20).
 
6.  Replace Pilot Orifice - Using a 7/16” open-end wrench, re-
move the pilot burner hood. Replace the pilot orifice with the 
one supplied in the propane conversion kit. Then, reinstall 
the pilot burner hood. Ensure that the mark on the pilot hood 
is lined up with the mark on the pilot mounting plate.