Monessen Hearth TPB18 ユーザーズマニュアル

ページ / 42
70D0004 
21
ELECTRICAL WIRING (MILLI-VOLT)
The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO OPER-
ATE.
CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT
  1.  Use 18 awg, two-wire cable, 15 feet maximum length.
  2.  At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to 
TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of 
the unit. The color of the wires does not matter. 
Figure 17 - Wiring Diagram
Note: Log switch wires are not factory connected. 
Connect log switch wires to the TH/TP and TH valve terminals as shown.
CAUTION
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. Verify 
proper operation after servicing.
Log Switch
On/Off 
Switch or 
Optional 
Wall
Switch, 
Remote or 
T-Stat
ODS 
Pilot
Milli-volt 
Valve
 TH = 3
TP = 1
TP/TH = 2
ODS 
Pilot