ELECTRICAL WIRING (MILLI-VOLT)
CONNECTING REMOTE RECEIVER
  1.  Set remote receiver. See instructions included in receiver kit. 
  2.  Connect the two (2) 1/4" female connectors to the TP/TH and TH terminals on the control valve.
Figure 18 - Installing Remote Receiver 
Remote 
Receiver 
Remote 
Wire 
Connectors
A.  COMPLETE MILLI-VOLT SYSTEM CHECK 
   
(“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON)
 
a.  If the reading is more than 175 milli-volts and the automatic valve still does not come on, replace the control.
 
b.  If the closed circuit reading (“A” reading) is less than 175 milli-volts, determine cause for low reading, proceed to 
Section B below. 
B.  Thermopile Output Reading Check 
(“B” Reading - Thermostat contacts OPEN - Main burner OFF)
 
1.  Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot 
voltage, 500 milli-volts minimum. If the minimum milli-volt reading is not obtainable, replace pilot.
CHECKING SYSTEM OPERATION
The milli-volt system and individual com-
ponents may be checked with a milli-volt 
meter having a 0-1000 mV range. Conduct 
each check shown in chart below by con-
nection meter test leads to terminals as 
indicated.
CHECK 
TEST
TO TEST
CONNECT 
METER LEADS 
TO TERMINALS
SWITCH OR 
THERMOSTAT 
CONTACTS
METER 
READING 
SHOULD BE
A
COMPLETE 
SYSTEM
2 & 3
CLOSED
MINIMUM 175
B
THERMOPILE 
OUTPUT
1 & 2
OPEN
MINIMUM 500
Note: Heat reduces battery life. You can protect the  receiver and extend battery life by mounting receiver 
in wall or other location outside the fi replace. 