FMI VSGF36NRC ユーザーズマニュアル

ページ / 36
www.fmiproducts.com
121082-01K
24
Figure 41 - Correct 
Pilot Flame Pattern
Pilot Burner
Figure 42 - Incorrect 
Pilot Flame Pattern
Pilot 
Burner
Thermocouple
(Pilot May Vary From Ones Shown)
Figure 43 - Correct Burner Flame Pattern 
Figure 44 - Incorrect Burner Flame 
Pattern 
Yellow Tipping 
At Top of Blue 
Flame 
INSPECTING BURNERS 
Check pilot flame pattern and burner flame 
patterns often.
PILOT FLAME PATTERN
Figure 41 shows a correct pilot flame pattern. 
Figure 42 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching 
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools, 
the fireplace will shut down.
If pilot flame pattern is incorrect, as shown 
in Figure 42
•  turn fireplace off (see To Turn Off Gas to 
Appliance, page 21) 
•  see Troubleshooting, page 26
Note: The correct pilot flame on natural gas 
units will have a slight curve, but flame should 
be blue and have no yellow or orange color.
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame 
holes should be open with yellow flame pres-
ent. All round burner flame holes should be 
open with a small blue flame present. Some 
burner flame holes may become blocked 
by  debris  or  rust,  with  no  flame  present.  If 
so,  turn  off  heater  and  let  cool.  Remove 
blockage.  Blocked  burner  flame  holes  may 
create soot.
FRONT BURNER FLAME PATTERN
Figure 43 shows correct front burner flame 
pattern. Figure 44 shows incorrect front 
burner  flame  pattern. The  incorrect  burner 
flame pattern shows yellow tipping at top of 
blue flame.
If front burner flame pattern is incorrect, as 
shown in Figure 44
•  turn fireplace off (see To Turn Off Gas to 
Appliance, page 21) 
•  see Troubleshooting, page 26