TROUBLESHOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, 
there is no spark at ODS/
pilot.
1. Ignitor electrode not con-
nected to ignitor cable.
2. Ignitor cable pinched or 
wet.
3. Broken ignitor cable.
4. Bad ignitor.
5. Ignitor electrode positioned 
wrong.
6. Ignitor electrode broken.
7. Battery not installed, battery 
power low or battery not 
installed correctly.
1. Reconnect ignitor cable.
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry.
3. Replace ignitor cable.
4. Replace ignitor.
5. Replace pilot assembly.
6. Replace pilot assembly.
7. Install new alkaline battery in 
electronic ignitor. Verify bat-
tery is installed correctly.
When ignitor button is pressed, 
there is spark at ODS/pilot but 
no ignition.
1. Gas supply turned off or 
equipment  shutoff  valve 
closed.
2. Control knob not in PILOT 
position.
3. Control knob not pressed in 
while in PILOT position.
4. Air in gas lines when  
installed.
5. Depleted gas supply (pro-
pane/LP only).
6. ODS/pilot is clogged.
7. Gas regulator setting is not 
correct.
1. Turn on gas supply or open 
equipment shutoff valve.
2. Turn control knob to PILOT 
position.
3. Press in control knob while 
in PILOT position.
4. Continue holding down 
control knob. Repeat ignit-
ing operation until air is 
removed.
5. Contact local propane/LP 
gas company.
6. Clean ODS/pilot (see Clean-
ing and Maintenance, page 
25) or replace ODS/pilot 
assembly.
7. Replace gas regulator.