SPECIFICATIONS FOR THE RC/RH10/20/35/45/80/90 & RC11/12/21
When installing the RC/RH10/20/35/45/80/90 or the RC11/12/21 refer to 
the charts below for electrical and optional electric heat specifications.
* Note: Data will vary if alternate components (including compressor or motor) are used to meet production needs. 
Consult factory for current electrical specifications.
RC/RH10/20/35/45/80/90 & RC11/21 Electrical Specifications*
Model
Voltage/hz/ph
Evap Motor
Cond Motor
Compressor
Total
MCA Max Fuse
Min 
Voltage
Line Cord
Number
FLA
Hp
FLA
Hp
RLA
LRA
Amps
9
115/60/1
1.4
0.09
1.6
0.125
7.4
44
10.4
12.3
15
104
5-15P
208/230/60/1
0.6
0.08
0.72
0.125
4.1
20
5.4
6.4
15
197
6-15P
265/60/1
0.67
0.08
0.7
0.125
3.35
18
4.7
5.6
15
240
7-20P
12
115/60/1
1.4
0.09
1.6
0.125
9.7
54
12.7
15.1
20
104
5-20P
208/230/60/1
0.6
0.08
0.72
0.125
5.1
28
6.4
7.7
15
197
6-15P
265/60/1
0.67
0.08
0.7
0.125
4.25
26
5.6
6.7
15
240
7-20P
15
208/230/60/1
0.6
0.08
0.72
0.125
6.4
35
7.7
9.3
15
197
6-15P
265/60/1
0.67
0.08
0.7
0.125
5.4
32
6.8
8.1
15
240
7-20P
18
208/230/60/1
0.6
0.08
0.71
0.09
7.6
45
8.9
10.8
15
197
6-15P
265/60/1
0.67
0.08
0.71
0.09
6.3
32
7.7
9.3
15
240
7-20P
Note: 18,000 not available in heat pump application.
NEMA Specifications Non-Locking/Receptacles
 
RC/RH10/20/35/45/80/90 & RC11/12/21 Optional Electric Heat Specifications*
Heater No. Voltage Watts
Btuh
Amps
Total Heat
MCA
Max 
Fuse
Line 
Cord
Amps
2
208
1636
5600
7.9
8.5
10.4
15
6-15P
230
2000
6900
8.7
9.3
11.5
15
6-15P
265
2655
9100
10.0
10.7
13.2
15
7-20P
3
208
2454
8400
11.8
12.4
15.3
20
6-20P
230
3000
10300
13.0
13.6
16.9
20
6-20P
265
3983
13600
15.0
15.7
19.5
20
7-20P
4
208
3271
11200
15.7
16.3
20.3
25
6-30P
230
4000
13700
17.4
18.0
22.3
25
6-30P
265
5310
18200
20.0
20.7
25.7
30
7-30P
5
208
4089
14000
19.7
20.3
25.2
30
6-30P
230
5000
17100
21.7
22.3
27.8
30
6-30P
RC12 Electrical Specifications*
Model
Voltage/hz/ph
Evap Motor
Cond Motor
Compressor
Total
MCA
Max 
Fuse
Min 
Voltage
Line 
Cord
Number
FLA
Hp
FLA
Hp
RLA
LRA
Amps
12
208/230/60/1
0.6
0.08
0.71
0.09
5.1
28
6.4
7.7
15
197
6-15P
265/60/1
0.67 
0.08
0.71
0.09
4.25
26
5.6
6.7
15
240
7-20P
15
208/230/60/1
0.6
0.08
0.71
0.09
7.6
45
8.9
10.8
15
197
6-15P
265/60/1
0.67
0.08
0.71
0.09
6.3
32
7.7
9.3
15
240
7-20P