Friedrich ES12 ユーザーズマニュアル

ページ / 56
14
920-198-00
Figure J
AIR FILTER
RETURN AIR 
GRILLE LATCH
CORD 
CLAMP
ADJACENT 
SCREW HOLE
RETURN AIR 
GRILLE LATCH
CORD CLAMP
 
CHASSIS 
SEAL 
GASKET
FAR 
LEFT 
SCREW
ADJACENT 
SCREW 
HOLE
WHEN INSTALLING CHASSIS SEAL GASKET, 
BEGIN AT EITHER BOTTOM CORNER AND 
GO UP THE SIDE, ACROSS THE TOP, AND 
DOWN THE OPPOSITE SIDE.
STEP 16    OPTIONAL: The factory assembles the supply cord so that 
it exits the left side of the unit. At the consumer’s discretion, 
the supply cord can be made to exit the right side of the unit. 
To do this, remove the black rubber coated cord clamp from 
under the far left screw (See Figure 
I). Replace this screw 
back into the far left screw hole. Route the supply cord over 
the top of the return air grille latches and reattach the clamp 
to the adjacent screw hole (Figures 
I & J). Detach the right 
side cord clamp, route the supply cord through it and reattach. 
The supply cord should be pulled taut so as not to rest on the 
return air grille latches.
Figure K
DISCHARGE 
AIR PLENUM
SLOT
TAB
SLOT
TAB
NOTE 2
RETURN 
AIR GRILLE
(NOTE 1)
LATCHES
NOTE 3
NOTE 1
RETURN 
AIR 
GRILLE
NOTE 4
SIDE VIEW
LATCH
NOTE 3
STEP 17   
Be sure the fi lter is in place before installing the return air grille 
(See Figure J), and that the electrical cord is properly routed 
so not to interfere with the installation. (See Step 16.) 
STEP 18   
Pick up the grille by sup port ing it from both sides near the bottom 
(See Figure K, Note 1.) Lift return air grille and insert the grille's 
tabs into the bottom slots of the discharge plenum (See Figure K, 
Note 2). Snap the grille into place by pushing the grille up and onto 
the unit's latches at the bottom (See Figure K, Notes 3 and 4).
STEP 19   
Refer to the Operating Instructions beginning on page 3.
Figure 
I